Operational Recommendations

5.1 

Do not start up the equipment dry

. Vent air from the casing of the pump and the seal chamber 

before startup. Circulate clean product or a clean fluid from an external source through the seal 
chamber whenever the equipment is in operation, API Plan 11 or 32.

5.2 

If the seal runs hot, check for proper seal setting, seal housing dimensions, and check the 
bypass or flush line for obstructions. Do not allow the equipment to run for any extended  
time if the seal gets hot or squeals.

For special problems encountered during installation, contact your nearest Flowserve Sales and 
Service Representative or Authorized Distributor.

6

Содержание BPO

Страница 1: ...3 Remove existing sealing arrangement mechanical seal or otherwise Clean seal chamber and shaft thoroughly 1 4 Inspect surfaces under gaskets to ensure they are free from pits or scratches Break all...

Страница 2: ...is found outside the general range contact the equipment manufacturer and your Flowserve representative to verify the equipment s suitability for the seal Seal chamber squareness to the shaft centerli...

Страница 3: ...Handle PTFE U cup rings and Durafite rotating face gaskets with extreme care PTFE U cup rings must be assembled individually and not pushed on the shaft or sleeve while they are installed on the rotat...

Страница 4: ...pring holder at reference mark B Figure 5 and tighten set screws firmly and evenly The rotating component assembly is now in the proper position to provide the correct setting and spring compression f...

Страница 5: ...al 4 6 Set the back of the spring holder at reference mark B Figure 5 and tighten set screws firmly and evenly In cases where the spring holder is provided with drive slots to engage with the pins the...

Страница 6: ...mber whenever the equipment is in operation API Plan 11 or 32 5 2 If the seal runs hot check for proper seal setting seal housing dimensions and check the bypass or flush line for obstructions Do not...

Страница 7: ...B M number A spare backup seal should be stocked to reduce repair time When seals are returned to Flowserve for repair decontaminate the seal assembly and include an order marked Repair or Replace A s...

Страница 8: ...tractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed to be accurate they are su...

Отзывы: