background image

4

Double Suction and Multistage Horizontal Split Case Pumps (2 boxes)

3.1  

  Scribe mark A 

on the shaft or sleeve to line up with the face of the seal housing.  

3.2  

  Scribe mark B 

at the seal setting point shown enclosed in a rectangular box on the assembly 

drawing included with the

 

seal. This seal setting dimension is measured from the face of the  

seal housing to the back of the spring holder. The back of the spring holder will be located at 
this point.

3.3  

  Lubricate the shaft

 or sleeve lightly with the lubricant provided with the seal before installing 

any seal parts.    

3.4  

  Install the rotating face gasket

 into the bore of the rotating face.

3.5  

  Install the rotating seal components

 on the shaft or sleeve in the proper sequence. Handle 

PTFE U-cup rings and Durafite rotating face gaskets with extreme care. PTFE U-cup rings must 
be assembled individually and not pushed on the shaft or sleeve while they are installed in the 
rotating face. Avoid nicking or pinching either lip of the U-ring. Use both U-cup rings, they work 
together to form an effective seal.

3.6   Set the back of the spring holder at reference mark B, Figure 5, and tighten set screws firmly 

and evenly. The rotating component assembly is now in the proper position to provide the 
correct setting and spring compression for final assembly.  

3.7 

   Lightly lubricate O-ring or Duraflex stationary face gaskets. 

 3.8    Press the stationary face into the gland 

(flexibly mounted face only). Use hand pressure only. 

Where a face has an O-ring mounting on the back shoulder, it is usually better to nest this O-ring 
into the gland cavity and then push the face into the nested O-ring.

3.9  

  Wipe the seal faces

 clean with alcohol before completing equipment assembly. Seal faces 

should not be lubricated, but should be left clean and dry.

3.10 

   Position the gland

 to the face of the seal housing. Be sure the gland pilot is properly engaged. 

Tighten the gland stud nuts 

evenly, cross stagger the adjustment of the nuts. Follow the  

equipment manufacturer's recommendations for gland stud nut torque. In the absence of 
recommendations, gland nuts should only be torqued to establish a leak tight seal at the gland 
gasket. Proper gland bolt adjustment is especially important with clamp style stationary faces 
where excessive torque may damage the face.  

3.11  

  Assemble the pump

.

3.12  

  See Operational Recommendations

 before starting pump.

Содержание BPO

Страница 1: ...3 Remove existing sealing arrangement mechanical seal or otherwise Clean seal chamber and shaft thoroughly 1 4 Inspect surfaces under gaskets to ensure they are free from pits or scratches Break all...

Страница 2: ...is found outside the general range contact the equipment manufacturer and your Flowserve representative to verify the equipment s suitability for the seal Seal chamber squareness to the shaft centerli...

Страница 3: ...Handle PTFE U cup rings and Durafite rotating face gaskets with extreme care PTFE U cup rings must be assembled individually and not pushed on the shaft or sleeve while they are installed on the rotat...

Страница 4: ...pring holder at reference mark B Figure 5 and tighten set screws firmly and evenly The rotating component assembly is now in the proper position to provide the correct setting and spring compression f...

Страница 5: ...al 4 6 Set the back of the spring holder at reference mark B Figure 5 and tighten set screws firmly and evenly In cases where the spring holder is provided with drive slots to engage with the pins the...

Страница 6: ...mber whenever the equipment is in operation API Plan 11 or 32 5 2 If the seal runs hot check for proper seal setting seal housing dimensions and check the bypass or flush line for obstructions Do not...

Страница 7: ...B M number A spare backup seal should be stocked to reduce repair time When seals are returned to Flowserve for repair decontaminate the seal assembly and include an order marked Repair or Replace A s...

Страница 8: ...tractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed to be accurate they are su...

Отзывы: