Operation 5
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
1. The shaft seal depends on water for
lubrication. Do not operate the pump unless
it is submerged in water; running it dry may
damage the seal.
2. If the pump overheats, an automatic-reset
thermal protector cuts off the power and stops
the motor before it can be damaged. The motor
will automatically restart when it cools. If the
protector trips repeatedly, unplug the pump,
remove it from the sump, and check it for
the cause of the difficulty. Low voltage, long
extension cords, clogged impeller, very low lift,
a plugged or frozen discharge pipe, etc., can
all cause cycling and overheating.
3. This pump will not remove all the water in the
sump. If you are running the pump manually
and water stops coming out of the discharge,
the pump has probably run dry. Shut it off
immediately and check the water level.
Performance
GPH At Total Feet Of Lift (See Figure 7)
Model
5 ft.
10 ft.
15 ft.
20 ft.
No flow
at height
shown
below
Capacity Gallons/Hour
FPSC2200A
4,020
3,540
3,000
1,800
26’
FPSC2250A
4,020
3,540
3,000
1,800
26’
FPSC3200A
4,380
3,840
3,300
2,340
28’
FPSC3250A
4,380
3,840
3,300
2,340
28’
FPSC4550A
4,700
4,100
3,500
2,820
32’
Electrical & Switch Specifications
Model
Motor
HP
Motor
Full
Load
Amps
Individual
Branch
Circuit
Req.
(Amps)
*Switch Setting
in inches
Water Level
For:
On
Off
FPSC2200A
1/3
6.9
15
15”
7”
FPSC2250A
1/3
6.9
15
6-1/2”
3”
FPSC3200A
1/2
7.0
15
15”
7”
FPSC3250A
1/2
7.0
15
6-1/2”
3”
FPSC4550A
3/4
7.7
15
6-1/2”
3”
Sump
Pit
Check Valve
(Install Vertically)
Basement
Floor
Discharge
Pipe
Lift
Figure 7 – LIFT: Lift is the vertical distance the
pump actually lifts water. The higher the lift, the
lower the flow.
NOTICE : The friction caused by water running
through the pipe will also, on longer pipe runs,
reduce the flow.