4.0 – K4 Pump Controller
CAUTION
!
The K4 VFD Controller has been tested and configured using 120VAC line power and may not be
configured for your line voltage.
CHECK THE POSITION OF THE LINE VOLTAGE SELECT JUMPER ON THE MAIN BOARD
PRIOR TO APPLYING POWER!
Failure to do so may cause permanent damage to the VFD.
4.1 Operation and Wiring
For complete details about the motor drive controller please refer to the included K4 SERIES Operating
Instructions booklet.
IMPORTANT: Make sure the Mains voltage jumper is in the correct location for the supplied
voltage. See the K4 drive operating instructions booklet for details.
Shown here are program settings specific to the operation with the V21 Peristaltic Pump.
4.2 Programming
K4 Default Program Settings
0.04 = 0000 GFCI disabled, enable if power pump through GFCI mains circuit (some additional noise from the drive is
normal).
1.00 = 0001 Remote Start/Stop contacts enable (CHANGE TO 0000 to use 4-20 with manual start/stop)
1.05 = 0003 Power fail auto restart
2.00 = 0003 Freq Control Analog 2 (4-20mA)
2.01 = 0001 Speed change w/o pressing enter
2.02 = 0002 Enable external Local/Remote switching
3.00 = 0005 Stored Set Frequency (5hz)
3.02 = 0100 Upper Frequency Limit
4.00 = 0000 Display in user defined units (Hz)
5.00 = 0000 Enable Run Relay N.O.
7.03 = 0010 Remote Start/Stop - N.O. Start
7.04 = 0000 External Local/Remote Select OFF (13 for remote auto select)
7.06 = 0008 External Fault input select
8.00 = 0001 NC Fault Relay
8.01 = 0009 Enable Status Output
9.07 = 0020 4-20mA Input
8.09* = 0002 When speed feedback 4-20ma output is connected
NOTES:
*8.09 = 0000 to avoid fault when 4-20mA Output is disconnected when not using 4-20mA output
Keypad speed can only be changed in local mode
For manual speed with remote start/stop set 2.00 to 0000
For remote (4-20ma) speed with manual (keypad) start/stop set 1.00 to 0000
Large hose pumps - Boost Value 3.11 default 7, up to 12 or higher
6.05 = 1010 reset to Flomotion Defaults
pg. 17
Содержание V21