Flomec OM025 Скачать руководство пользователя страница 2

  

 

 

 

 

 

 

 

1      Index / contents 

 
 
 
 

 

 

 

 

 

 

 

           

1.0

   

General

  

 

 

 

 

 

              Page 

 

1.1  

Overview   

 

 

 

 

  

1.2            Operating principal 

 

 

 

 

1.3  

Model number information 

 

 

 

 

1.4  

Specifications 

 

 

 

 

 
 

2.0   Installation 

 

2.1  

Mechanical installation 

 

 

 

2.1.1  

Orientation 

 

 

 

 

5

 

2.1.2  

Flow conditioning & locations 

 

 

 

6

 

2.2  

Electrical installation   

 

 

 

2.2.1  

Instrument cable 

 

 

 

 

2.2.2  

Hazardous area wiring 

 

 

 

2.3  

Pulse output selection for pulse meters 

 

 

2.3.1  

Hall sensor pulse output 

 

 

 

2.3.2  

Reed switch pulse output 

 

 

 

2.3.3 

Quadrature pulse output 

 

 

 

2.3.4 

Signal integrity verification 

 

 

 

2.3.5 

Bi-directional flow 

 

 

 

 

2.4  

Meters fitted with integral instruments 

 

 

9  

2.4.1  

Meter calibration factor 

(K-factor or scale Factor) 

 

 
 

3.0   Commissioning  

 

 

 

 

 

10 

 
 

4.0

 

Maintenance   

 

 

 

 

 

10

 

 

   

4.1  

Disassembly of pulse meter 

 

 

 

11 

    

4.2  

Disassembly of meters fitted with an instrument 

 

11 

4.3   

Exploded view & spare parts 

 

 

         

11 &

 

12 

4.4   

Inspection & exploded view 

 

 

 

13

 

    

4.5  

Re-assembly of meter 

 

 

 

13 

 
 

5.0   Fault Finding   

 

 

 

 

 

14 

 
 

5.1 

Trouble shooting 

 

 

 

 

15  

 
 
 
 
 
 

General      2 
 
 

General 
 
1.1  Overview 

 
The Oval gear meter is a precise positive displacement flowmeter incorporating a pair of oval geared rotors. These 
meters are capable of measuring the flow of a broad range of clean liquids. 
 
Stainless Steel flowmeters are suited to most water based products and chemicals and aluminum meters are 
suitable for fuels, fuel oils & lubricating liquids. 
 
The flowmeter is available as a blind meter with pulse output capable of interfacing to most monitoring and control 
instrumentation or the meter can be fitted with or supplied with instruments such as totalisers, rate totalisers or 
batch controllers.These instruments also have monitoring and control output options including 4-20mA, scaled 
pulse, flowrate alarms and batch control logic 

(preset metering

). 

 
If your flowmeter is fitted or supplied with an instrument please also refer to the relevant instrument instruction 
manual. 
 
These flowmeters can be installed within hazardous areas by using the reed switch pulse output in Intrinsically 
Safe loops or fitting Intrinsically Safe certified Instruments. Please consult the factory for the availability of 
flameproof models.   
  

1.2  Operating Principle 

 
The Oval gear are positive displacement flowmeters where the passage of liquid causes two oval geared rotors to 
rotate within a precision measuring chamber and with each rotation a fixed volume of liquid is displaced passing 
through the meter. Magnets embedded within the rotors initiate a high resolution pulse train output. The pulse 
output can be wired directly to process control and monitoring equipment or can be used as an input to 
instruments supplied with or fitted directly to the meter.  
 
The benefits of this technology allow precise flow measurement and dispensing of most clean liquids irrespective 
of their conductivity, with other liquid characteristics having nil or minimal effect on meter performance. This 
metering technology does not require flow profile conditioning as required with alternative flow technologies 
making the installation relatively compact and low cost. 
 
        
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATION : 

 

Liquid travels around the crescent 
shaped chambers created by the  
rotational movement of the rotors  

liquid exits the  
measuring chamber 

liquid in transit 

flow 

liquid entering  
measuring chamber 

Содержание OM025

Страница 1: ...w flomec com au USA 916 Belcher Drive Pelham AL 35124 USA Tel 1 205 378 1050 Fax 1 205 685 3001 Email customerservice trimecus com Website www trimecus com Distributed by Each meter has been calibrated on mineral oil and will contain a small amount of oil residue The oil used is Castrol Diesel Calibration Fluid 4113 product code 055830 Medium capacity positive displacement flowmeters OVAL GEAR SEE...

Страница 2: ...otalisers rate totalisers or batch controllers These instruments also have monitoring and control output options including 4 20mA scaled pulse flowrate alarms and batch control logic preset metering If your flowmeter is fitted or supplied with an instrument please also refer to the relevant instrument instruction manual These flowmeters can be installed within hazardous areas by using the reed swi...

Страница 3: ...en collector phased outputs 4 dc 2 stage batch controller OM040 OM050 accum reset totals pulse output IECEX ATEX approved IECEX ATEX approved IECEX ATEX approved Specifications Model prefix OM015 OM025 OM040 OM050 Nominal size inches 15mm 1 2 25mm 1 40mm 11 2 50mm 2 Flowrange litres min 1 40 10 150 15 250 30 450 Flowrange USGM 0 26 10 6 2 6 40 4 66 8 120 Accuracy 3cp Repeatability Temperature rang...

Страница 4: ...nd air entrapment which can result in erroneous readings or damage the meter on start up Process or safety critical meters should be installed in a by pass section of pipe with isolation valves to enable the meter to be isolated and serviced as required A by pass installation also allows purging of the system during commissioning see Commissioning The meter must be appropriately rated and is typic...

Страница 5: ...stor typically greater than 10K ohms in most instruments which ties the open collector to the available dc voltage level when the Hall sensor is not energized When energized the open collector output is pulled to ground through the emitter 0V 2 3 2 Reed Switch Pulse Output The reed switch output is a two wire normally open SPST voltage free contact ideal for installations without power or for use ...

Страница 6: ...ill have the relevant calibration factor entered into the program of the instrument Please refer to relevant instrument manual for programming details 10 Commissioning Maintenance 3 0 Commissioning Once the meter has been mechanically and electrically installed in accordance with this and any other relevant instrument manual s the meter is ready for commissioning The meter must NOT be run until th...

Страница 7: ...embly with rotor shafts Part No aluminum 1401096 1401094 1401092 stainless steel 1401097 1401093 2 Rotor assembly set aluminum rotors bearings 1424071 1424111 1424099 stainless steel rotors bearings 1424092 1424125 1524011 3 Body O ring size BS153 size BS245 size BS253 viton standard 13031531 13032451 13032531 teflon 13031533 13032453 13032533 4 Meter cap aluminum with M20 conduit entry 1302047 13...

Страница 8: ...tep 1 Check application installation and set up Refer to Mechanical Installation section for installation and application factors that may effect the meter operation including pulsation and air entrainment or incorrect meter selection including incorrect flow rate temperature and pressure or materials compatibility Refer to Electrical Installation for correct wiring Step 2 Check for blockages The ...

Страница 9: ...rminations wires for continuity 1 Rotors fouled 1 Check that rounded teeth are towards base of chamber 2 Check for obstruction due to foreign particles 3 Clean repair or replace rotors 2 1 See instructions for reassembly of meter with particular emphisis on positioning of rotors magnets 3 1 Check terminal connections solder joints 2 Ensure dc voltage is available at Vdc 0v and receiving instrument...

Отзывы: