Page 28
FL_F116P_v1702_01_EN
Type AA
An active 4-20mA signal proportional to the (differential or summed) flow rate is available with this
option. When the output is disabled, a 3.5mA signal will be generated on these terminals.
Max. driving capacity 1000 Ohm @ 24VDC. (Requires power supply type PD/PF/PM).
Fig. 12: Terminal connections - 4-20mA analog output (typical)
Type AB
An active 0-20mA signal proportional to the (differential or summed) flow rate is available with this
option. Max. driving capacity 1000 Ohm @ 24VDC. (Requires power supply type PD/PF/PM).
Fig. 13: Terminal connections - Active 0-20mA analog output (typical)
Type AF
For the Intrinsically safe floating 4-20mA signal: please read Chapter 5.
Type AI
An isolated 4-20mA signal proportional to the (differential or summed) flow rate is available with this
option. When the output is disabled, a 3.5mA signal will be generated on these terminals.
Max. driving capacity 1000 Ohm @ 30VDC.
This option can be used with a battery powered unit but the battery life time is about 2 -3 years.
Fig. 14: Terminal connections - Isolated 4-20mA analog output (typical)