4—Tau 640 Digital Data Channel
Tau 640 User’s Manual
4-10
June 2011
TAU-0640-00-10, version 110
Row 0 Row 1
Pixel 0,0 Pixel 0,1
Row 511
Pixel 0,639
External Frame sync (not required)
Idle time
Idle time
Frame time
Line time
Idle time
Figure 4-5: Digital Data Format
SD_FSYNC
SD_FSYNC
Inverted Mode
Toc = 1 to 5 ns
SD_CLK
SD_DATA &
Toc = 1 to 5 ns
SD_CLK
SD_DATA &
Normal Mode
Figure 4-6: Detailed Digital Data Timing
The LVDS data is clocked out of the camera on the rising edge of the
data clock and should be sampled on the falling edge. There is no delay in
the data with respect to the data clock.