![FLIR Tau 640 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/flir/tau-640/tau-640_user-manual_2306222048.webp)
4—Tau 640 Digital Data Channel
Tau 640 User’s Manual
4-8
June 2011
TAU-0640-00-10, version 110
4.5.1 Using the Legacy LVDS Digital Data Channel
Note
Follow the steps in paragraph 3.1 “Operation of the Tau 640 Camera using the USB Interface”
on page 3-1 for basic operation of the Tau 640 camera. After verifying that the camera is
operating properly, disconnect power from the Tau 640 camera.
Step 1
Connect the SIPO accessory module directly to the three-row DB-15 connector on the
Interface Module labeled
DIGITAL DATA
as shown below. A cable is NOT required.
Step 2
Connect the parallel data cable to the mating connector on the SIPO module. Connect
the other end to the frame-grabber board installed in your PC.
Note
Step 3
Follow instructions included with the frame grabber for selecting the camera
configuration file included with the SIPO module.
Step 4
Reapply power to the Interface Module. This will power-up both the Tau 640 camera
and the SIPO module, and digital data will begin streaming.
Step 5
If desired, change the digital data mode using the FLIR Camera Controller GUI
software in the
Digital Video
tab.
The following instructions assume that you have purchased the optional Tau 640 Photon
Replicator Kit; and have the Photon Legacy serial-to-parallel-out (SIPO) accessory module with
parallel data cable and the appropriate Photon Accessory Kit (including the I/O Module and
cables shown below. If you are using custom cabling and/or interface electronics, contact
FLIR Customer Support at (805) 964-9797 if you need additional assistance.
The parallel data cable is specific to a particular frame grabber. Contact the manufacturer of
the frame grabber to make sure you have the correct cable.
To Photon
To frame grabber board
I/O Module
SIPO Module
Replicator Board