910-0001-00-INS -R02
Page 45 of 53
Information contained in this document pertains to a Canadian origin product that is controlled as "dual use" by the Canadian
government. However, when in the United States or possessed by a US person, it may be considered a defense article from the US Government's
perspective. US government authorization may be required for re-transfer to a foreign person. If you have any questions, please contact FLIR's
Global Trade Compliance group at [email protected] .
6
TROUBLESHOOTING
The following tables cover the Built-In Test (BIT) error codes and their description and solutions for
resolving problems.
Note
In the event that any of these error codes are reported, follow the procedure below.
Step 1
Try re-initializing the system.
Step 2
If the error persists, gather the following information:
•
Physical installation
•
Network topology
•
Software version
•
Radar serial number
•
Conditions under which the error occurred
•
Any relevant application/system logs
Step 3
Contact Customer Support.
Error Code format: <Failure Category> . <Sub-Assembly code> <number>
Failure
Category
Description
0
Host-Equipment Continuity
1
Radar Temperature
2
Radar Transmitter/Receiver Current
3
Radar Transmitter/Receiver Voltage
4
Radar Scan Monitoring
5
Radar RF Signal Monitoring
6
Embedded GPS Communication
7
Radar RF Signal Synchronization
8
Radar Time Synchronization
9
Configuration and Parameters
10
Memory Check (RAM, Flash, etc.)
Table 12 - Radar Failure Category Definition
Содержание Ranger R Series
Страница 53: ......