March 10, 2019
84
Accessing the CM-330X via a Web Browser
CM-3304/CM-3308 User and Installation Guide
·
Reset Max and Min Object size
·
Define Object in region duration Time
·
Configure advanced settings, including sensitivity, area masking, reset scene and arming schedule
·
Analytics actions
Use the Object Dropped rule to secure an area against suspicious objects and litter. For example, a bus
station or a public square.
On the initial setup step, set minimum and maximum object sizes that correspond to the potential threat
(smaller than people). Draw a shape using up to 8 points to cover the protected area. The minimum
duration in region ranges between 5 and 900 seconds – use a reasonable value to avoid false alarms.
Once the rule has been defined, do not disturb the scene for about 30 seconds to a minute.
See the
section for more information on the setup process:
Zone Settings:
This section allows the user to create an area using between 3 and 8 points in order to configure the
desired space
Clicking on the video scene will produce points for area creation. Once three points are selected, a full area
will appear. Clicking more, will create more points creating more complex shapes up to 8 points
Pressing the
Delete
button
clears the area entirely, starting the area configuration from nothing.
Basic Settings:
For general "Basic Settings" see
Duration in Region
This section is used to configure the duration of an object left in a defined region in order for a rule to be
triggered. This can be changed from the default of 15 second by dragging the slider or typing a number into
the text box.