RIGHTS AND LIABILITIES 

 

All rights reserved. 

 

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by 
any means, mechanical, photocopying, recording, or otherwise, without the prior written permission of Flintec 
GmbH 

 

No patent liability is assumed with respect to the use of the information contained herein. While every 
precaution has been taken in the preparation of this book, FLINTEC assumes no responsibility for errors or 
omissions. Neither is any liability assumed for damages resulting from the use of the information contained 
herein. 

 

The information herein is believed to be both accurate and reliable. FLINTEC, however, would be obliged to 
be informed if any errors occur. FLINTEC cannot accept any liability for direct or indirect damages resulting 
from the use of this manual. 

 

FLINTEC reserves the right to revise this manual and alter its content without notification at any time. 

 

Neither FLINTEC nor its affiliates shall be liable to the purchaser of this product or third parties for damages, 
losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of 
this product or unauthorized modifications, repairs, or alterations to this product, or failure to strictly comply 
with FLINTEC operating and maintenance instructions. 

 

FLINTEC shall not be liable against any damages or problems arising from the use of any options or any 
consumable products other than those designated as Original FLINTEC Products. 

 

NOTICE: The contents of this manual are subject to change without notice. 

 
 

Copyright © 2007 by Flintec GmbH, 74909 Meckesheim, Bemannsbruch 9, Germany 

 

S

AFETY 

I

NSTRUCTIONS

 

 

 

CAUTION

 

READ this manual BEFORE operating or servicing this equipment. FOLLOW 

these instructions carefully. SAVE this manual for future reference. DO NOT allow untrained 
personnel to operate, clean, inspect, maintain, service, or tamper with this equipment. 
ALWAYS DISCONNECT this equipment from the power source before cleaning or performing 
maintenance. CALL FLINTEC ENGINEERING for parts, information, and service. 

 

 

WARNING 

ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THIS EQUIPMENT. 

EXERCISE CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE 
MADE WITH POWER ON. FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT 
IN BODILY HARM. 

 

 

WARNING 

FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT 

TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG. 

 

 

WARNING 

DISCONNECT ALL POWER TO THIS UNIT BEFORE REMOVING THE 

FUSE OR SERVICING. 

 

 

WARNING 

BEFORE CONNECTING/DISCONNECTING ANY INTERNAL ELECTRONIC  

COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT 
ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY 
CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE 
PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE 
EQUIPMENT OR BODILY HARM. 

 

 

CAUTION 

OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE 

DEVICES. 

 

 

Junction Box Type KPF – Technical Manual, Rev. 1.11   July 2008

 

Page 2 of 8

Содержание KPF-4

Страница 1: ...Junction Box Type KPF 4 KPF 6 KPF 8 KPF 10 T TE EC CH HN NI IC CA AL L M MA AN NU UA AL L Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Страница 2: ...the use of any options or any consumable products other than those designated as Original FLINTEC Products NOTICE The contents of this manual are subject to change without notice Copyright 2007 by Fli...

Страница 3: ...4 MECHANICAL INSTALLATION 4 ELECTRICAL CONNECTIONS 4 LOAD CELL CABLE CONNECTION 5 OUTPUT CABLE CONNECTION 5 CORNER CORRECTION AT SCALES WITH FLINTEC LOAD CELLS 6 CLOSING THE JUNCTION BOX 6 SUMMARY OF...

Страница 4: ...h is more or less dry and protected from environmental stress The junction box itself has to be mounted with the cable glands showing vertically to the bottom A flooding or any tensile load on the cab...

Страница 5: ...ube significantly Unused cable inlets must be closed by the delivered blind plugs If the cable gland nuts are correctly tightened the sealing part of the cable gland must constrict the blind plug sign...

Страница 6: ...kg test load 0 1 kg 500 kg x 1100 0 22 Example 2 400 load cell 10 kg corner error with 5000 kg test load 10 kg 5000 kg x 400 0 8 4 Install the correction resistor into the junction box for the corresp...

Страница 7: ...ing hole must be closed by a blind plug and a gasket 6 The earth screw must be electrically connected with protective earth potential equalisation For doing this only the upper nut should be loosened...

Страница 8: ...ke service kit no 1 but without ring spanner SSG19 Service kit no 3 Article no 5200 U3 for load cells with maximum capacity in the range from 7 5 t to 22 5 t with ring spanner Parts list Description A...