13
PF7/PF7+ Peristaltic Filler with QC14 Pumphead User Manual
4.3 Tube bridge open indicator
There are rotating parts inside the pumphead. Isolate the pump
from input power before opening the pumphead tube bridge or
access tray.
The pumphead features magnetic safety switches in both the tube
bridge and access tray. If the tube bridge or access tray are
opened the pump will not operate and a warning screen is
displayed.
The tube bridge must be closed for the warning screen to clear and the pump to
start.
Additionally for the QC14 pumphead the access tray must be closed for the warning
screen to clear and the pump to start.
4.4 Shipping and handling
The pump does not require special precautions to ship.
The PF7 contains a non-replaceable Manganese Dioxide Lithium Battery (Li/MnO
2
),
IEC CR2032, with a typical capacity of 225 mAh, containing 0.07 g of Lithium.
The PF7+ contains a non- replaceable Manganese Dioxide Lithium Battery
(Li/MnO
2
), IEC CR2016, with a typical capacity of 140 mAh, containing 0.0036 g of
Lithium.