before installation, and read the Fibo Seal Technical Datasheet for proper handling and storage of the sealant. The panels should be 

installed at temperatures no less than 18°C / 65°F and 45%RH. Panels should not be installed in areas where the temperature may 

drop below freezing (0°C / 32°F). Failure to follow this recommendation could adversely affect the sealant function and change the 

dimension of the panel, causing it to warp.
• 

Eye Protection:

 Be sure to use all personal protective equipment to ensure your own safety. To avoid eye injury, always wear 

protective glasses with side shields when using power tools. Also, make sure no one else can be injured by flying particles when using 

power tools.
• 

Fire Hazard:

 Personal injury or death can result from a fire caused by flammable liquids. Cleaners or solvents can be highly explosive, 

resulting in personal injury or even death when not used properly. Clean up any flammable substances immediately. Sparks or open 

flames can cause flammable substances to ignite. DO NOT smoke while working on or near any flammable substances.

• 

Solvent Hazard:

 Follow all the manufacturer’s safety instructions for Fibo Seal, Fibo Adhesive, Fibo Clean and Fibo Wipes. Fibo Clean 

is both flammable and hazardous to breathe. It may cause dizziness so make sure to have a proper ventilated room when in use. Fibo 

Wipes may cause dry skin with prolonged skin contact. Personal injury can result from improper handling or use of products.Always 

follow the manufacturer’s recommendations for the safe use of these products. Ventilate any work area before beginning to apply 

sealant, cleaning agents or solvents.
• 

Dust Hazard:

 When cutting or drilling a Fibo product, use a dust collection method to minimize airborne dust particles. Always use an 

OSHA approved dust mask when cutting, drilling or sanding Fibo products.

• 

Power Tool Hazard:

 To prevent personal injury or possible death, always follow the electrical safety recommendations for the power 

tool’s manufacturer. Do not use power tools in an unsafe manner. Power tools should only be connected to a circuit protected by a 

ground-fault circuit interrupter (GFCI).
• 

Shock Hazard:

 Never use electric power tools around water, condensation, or other liquids. Electric shock can cause severe burns, 

significant injuries, and even death. If an extension cord is required always use an OSHA approved extension cord. Power cords should 

only be connected to a circuit protected by a ground-fault circuit interrupter (GFCI).

HELPFUL HINTS

• 

Ensure construction is correctly sized, plumb and square.

•  Allow enough time for the parts in this kit to adjust to room temperature. Recommended minimum time is set to 72 hours. 
• 

We do not recommend installation of this product at temperatures below 18°C / 65°F and below 40% RH.

•  Do not use stored Fibo panels as an underlayer for cutting other Fibo panels. Make sure to have another proper underlayer available.
•  Make sure the backwall is level and the corners are at 90º.
• 

UV light prevents the sealant from yellowing. Open all blinds and curtains during the installation and drying time if possible. 

WARNING: 

• 

Fumes Hazard:

 The fumes from the Fibo Clean used by the installer can be harmful if used in an unventilated room. Always work in a 

well-ventilated area. To keep the area well-ventilated, open windows and use exhaust fans. If adequate ventilation is not achievable or 

practical, use respiratory protective equipment

CONSIGNES DE SÉCURITÉ

Si le produit est correctement installé et entretenu comme indiqué dans ces instructions, il n’y aura pas de dégâts d’eau.

ATTENTION:

Pour éviter d’endommager le produit, tout risque de blessures graves ou fatales, lire attentivement, comprendre et suivre toutes les 

instructions de ce guide avant d’installer le ou les produits. 
Lire et comprendre les instructions et les avertissements concernant les liquides de nettoyage et les outils utilisés pour cette 

installation. Le bon usage des outils et des produits décrits dans ce guide est votre responsabilité.

GARANTIE:

Pour toute information concernant la garantie des produits Fibo, veuillez visiter fleurco.com/fibofr.

AVIS IMPORTANT:

Indique que des dommages à l’équipement ou aux biens peuvent survenir si les instructions ne sont pas suivies.

MISE EN GARDE:

Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, peut entraîner des blessures. Elle peut également être 

utilisée pour signaler des pratiques dangereuses.

AVERTISSEMENT:

Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, pourrait entraîner des blessures graves ou la mort.
Utiliser les méthodes d’installation appropriées: Suivre toutes les instructions liées à la préparation des surfaces des murs. Le non-

respect de ces instructions pourrait entraîner le détachement des panneaux de la surface du mur suite à l’installation et causer des 

FRENCH / FRANÇAIS

Содержание FW10

Страница 1: ...1 INSTALLATION MANUAL GUIDE D INSTALLATION FW10 23 09 21...

Страница 2: ...ractices WARNING Indicates a potentially hazardous situation which if not avoided could result in serious injury or death Use proper installation methods Follow all instructions related to wall surfac...

Страница 3: ...ord is required always use an OSHA approved extension cord Power cords should only be connected to a circuit protected by a ground fault circuit interrupter GFCI HELPFUL HINTS Ensure construction is c...

Страница 4: ...s Risque li aux solvants Suivre toutes les instructions de s curit du fabricant pour le Fibo Seal Fibo Adhesive Fibo Clean et Fibo Wipes Fibo Clean est la fois inflammable et dangereux respirer il peu...

Страница 5: ...SCREWS FOR WOOD VIS POUR BOIS PENCIL CRAYON TAPE MEASURE RUBAN MESURER SCREWDRIVER TOURNEVIS CAULK GUN FUSIL CALFEUTRER HOLE SAW SCIE CLOCHE HACKSAW SCIE M TAUX OR OU CIRCULAR SAW SCIE CIRCULAIRE DRI...

Страница 6: ...PROFILE PROFIL DU COIN 1 2 BOTTOM TRACK PROFIL DU BAS 2 3 WALL 24 1040mm MUR 24 1040mm 5 4 L PROFILE PROFIL EN L 4 5 CORNER PROFILE SCREW VIS POUR PROFIL DU COIN 16 6 SCREW VIS 1 PACK 7 FIBO SEALANT...

Страница 7: ...ALL 24 1040mm MUR 24 1040mm 5 4 L PROFILE PROFIL EN L 4 5 CORNER PROFILE SCREW VIS POUR PROFIL DU COIN 16 6 SCREW VIS 1 PACK 7 FIBO SEALANT MASTIC FIBO 2 8 FIBO CLEANING LIQUID NETTOYANT FIBO 1 9 FIBO...

Страница 8: ...EXC DENT DE MASTIC SUR LE MUR NETTOYER IMM DIATEMENT EN SUIVANT LES TROIS TAPES DE LA M THODE FIBO DURING THE INSTALLATION CLEAN THE WALL EDGE WITH FIBO WIPES BEFORE SPREADING FIBO SEALANT EVENLY ALO...

Страница 9: ...LAT RAL MAX HEIGHT HAUTEUR MAX FB2 5PAN FB2 L INSTALLKIT XX 72X36 BASE 59 1 2 35 1 2 94 1 2 72X42 BASE 59 1 2 41 1 2 60X36 BASE 59 1 2 35 1 2 60X38 BASE 35 1 2 37 1 2 60X42 BASE 37 1 2 41 1 2 BACK WA...

Страница 10: ...r to previous step L paisseur d pend du type d installation se r f rer l tape pr c dente OSB OSB Base with integrated tiling flange Base avec bride de carrelage int gr e B GO TO PAGE 14 VOIR LA PAGE 1...

Страница 11: ...b a full sheet of OSB is usable Nous vous recommandons de couper les planches OSB en trois pour faciliter l insertion des cales en bois Cependant si les montants sont d aplomb une planche OSB en entie...

Страница 12: ...POUR INSTALLER LE PROFIL DU BAS A6 1 Measure the width of the back wall C 1 Mesurer la largeur du mur en arri re C 2 Measure the distance between the edge of the base to the back wall D 2 Mesurer la...

Страница 13: ...TO OBTAIN A 1 8 GAP WHICH WILL BE SEALED AT THE END OF THE INSTALLATION PLACER UN BLOCK NIVEAU TRANSPARENT DE 1 8 POUR OBTENIR UN CART QUI SERA REMPLI DE MASTIC FIBO LA FIN DE L INSTALLATION BACK VIE...

Страница 14: ...is usable Nous vous recommandons de couper les planches OSB en trois pour faciliter l insertion des cales en bois Cependant si les montants sont d aplomb une planche OSB en entier est utilisable MEAS...

Страница 15: ...LLUSTR 1 Measure the width of the back wall C 1 Mesurer la largeur du mur en arri re C 2 Measure the distance between the edge of the base to the back wall D 2 Mesurer la distance entre le bord de la...

Страница 16: ...INSTALLER L AUTRE PROFIL DU BAS 2 BACK VIEW VUE ARRI RE 1 12 SCREW EVERY 10 5 VISSER TOUS LES 10 5 10 1 2 BACK VIEW VUE ARRI RE 1 3 2 12 THE ENDS AT 45 OF THE TRACK MUST MEET AT THE CORNER PLACE FIBO...

Страница 17: ...all section s tongue and add the panel labels as illustrated Placer les murs A B C X et D de mani re ce que les rainures ne soient pas orient es vers les coins afin de recevoir la languette de la sect...

Страница 18: ...e groove of walls A B C X and D are oriented away from the corners in order to receive the following wall section s tongue and add the panel labels as illustrated Placer les murs A B C X et D de mani...

Страница 19: ...ET PROFILS DU COIN SUR LES PLANCHES OSB ET LES IDENTIFIER MEASURE AND MARK THE HEIGHT FOR H AND M MESURER ET MARQUER LA HAUTEUR DU H ET M 11 12 7 8 H Corner profile height Hauteur du profil du coin P...

Страница 20: ...ALWAYS CUT THE TOP OF THE WALL FOR FIBO PANELS TOUJOURS COUPER LE BORD SUP RIEUR POUR LES PANNEAUX FIBO FOR CORNER PROFILES CUT LENGHT EQUIVALENT TO M MINUS 3 8 POUR LES PROFILS DE COIN LONGUEUR DE C...

Страница 21: ...RACK MESURER PARTIR DU SEUIL MEASURE THE POSITION OF THE FAUCET MESURER LA POSITION DU ROBINET 15 16 MODEL MOD LE 60X36 72X36 APPLY FIBO SEALANT ALONG THE BORDER APPLIQUER DU MASTIC FIBO LE LONG DU BO...

Страница 22: ...L LE PROFIL DE COIN DOIT TRE ALIGN AVEC LE BORD SUP RIEUR DU MUR Top Haut APPLY FIBO SEALANT ALONG THE EDGE OF THE A WALL APPLIQUER DU MASTIC FIBO SUR LE BORD DU MUR A A SECURE THE CORNER PROFILE TO T...

Страница 23: ...ANT MASTIC FIBO SCREW EVERY 12 VISSER TOUS LES 12 12 A C B Spray clean the excess and wipe Vaporiser nettoyer l excedent et essuyer MODEL MOD LE 60X36 72X36 APPLY FIBO SEALANT ON THE BOTTOM TRACK AND...

Страница 24: ...s possible to position the panel and mark the distance directly see step 34 Il est possible de positionner le panneau et marquer directement la distance voir tape 34 MODEL MOD LE 60X36 72X36 W PASTE I...

Страница 25: ...AND CUT THE MEASURE H 1 4 ON THE REMAINING PANELS MESURER ET COUPER LA DISTANCE H 1 4 SUR LES PANNEAUX RESTANTS Use panel A as reference to cut the rest of the panels Utilisez le panneau A comme r f...

Страница 26: ...SUR LES PANNEAUX RESTANTS Use panel A as reference to cut the rest of the panels Utilisez le panneau A comme r f rence pour couper le reste des panneaux H 1 4 H 1 4 MODEL MOD LE 60X36 W PASTE IDENTIF...

Страница 27: ...mastic FIBO PRE DRILL BETWEEN 1 4 6mm AND 5 16 8mm FROM THE EDGE OF THE WALL AND SCREW EVERY 8 200mm PR PERCER ENTRE 1 4 6mm ET 5 16 8mm DU BORD DU MUR ET VISSER TOUS LES 8 200mm Spray clean the exce...

Страница 28: ...OUPE TEL QU ILLUSTRE TOP VIEW VUE DE DESSUS B On the wall edge that goes in the corner Sur le bord du mur qui va au coin On the bottom profile Sur le profil du bas A On the wall bottom edge Au bas du...

Страница 29: ...MUR AUX PLANCHES OSB ET ESSUYER L EXC DENT MODEL MOD LE 60X36 72X36 X C INSTALL X PANEL INSTALLER PANNEAU X Sealer Mastic On the bottom profile Sur le profil du bas A B On the wall edge connecting wi...

Страница 30: ...ALL D AND MARK THE CUTTING LINE TEMPORAIREMENT ASSEMBLER LE MUR D ET MARQUER LA LIGNE DE D COUP TOP VIEW VUE DE DESSUS PUT THE STICKER IDENTIFYING THE PART OF THE WALL THAT WILL BE KEPT COLLER L AUTOC...

Страница 31: ...BO SEALANT ALONG THE EDGES ON WALL D AND BOTTOM TRACK AND INSTALL APPLIQUER DU MASTIC FIBO SUR LE MUR D ET PROFIL DU BAS ET L INSTALLER On the wall edge connecting with X Sur le bord du mur en contact...

Страница 32: ...ENTRE 1 4 6mm ET 5 16 8mm DU BORD DU MUR ET VISSER ER VISER TOUS LES 8 200mm A C B Spray clean the excess and wipe Vaporiser nettoyer l excedent et essuyer PRE DRILL BETWEEN 1 4 6mm AND 5 16 8mm FROM...

Страница 33: ...L MOD LE 60X36 72X36 40 A C B Spray clean the excess and wipe Vaporiser nettoyer l excedent et essuyer ALL EXPOSED EDGES MUST BE COVERED BY FIBO SEALANT TOUS LES BORDS EXPOS S DOIVENT TRE RECOUVERTS P...

Страница 34: ...h sealant to uphold watertight integrity S assurer que la valve pour contr ler la temp rature passe travers l paisseur des planches OSB et du panneau Fibo et qu il reste suffisamment d espace pour ins...

Страница 35: ...35 PLACE THE WOODEN PANEL STICKER ON THE WALLS PLACER L AUTOCOLLANT PANNEAUX EN BOIS SUR LES MURS PLACE THE DESCRIPTIVE STICKER COLLER L AUTOCOLLANT 43...

Страница 36: ...so be cleaned regularly with the panels to prevent mold growth particularly the bead of sealant at the base of the panels where water is most likely to pool If the mold cannot be removed by cleaning a...

Страница 37: ...es nettoyants alcalins doux con us pour nettoyer l aluminium Mastic Le savon et les r sidus cutan s doivent tre enlev s du mastic fr quemment pour viter la croissance des moisissures Si le mastic est...

Страница 38: ...oyez que l tanch it des panneaux est affect e s assurer que la zone affect e reste au sec ou si ce n est pas possible couvrir la zone avec un mastic temporaire jusqu ce qu elle puisse tre valu e ou r...

Отзывы: