8
Trouble Shooting
CAUTION: ALWAYS disconnect air supply before performing any
service procedure.
Symptom
Probable Cause
Correction
Air leak
Loose screws
Tighten screws
Connector nipple loose
Tighten connector
Driver does not
Inadequate air supply
Verify and correct
fire, or is sluggish
supply and pressure
Inadequate lubrication
Put 1 or 2 drops of oil in
air supply connector
Frequent jams
Incorrect points
Use Fletcher brand
Points
Loose screws on Upper
Tighten screws
or Lower Guides
Foreign matter in
Open and clean
magazine
magazine
Foreign matter between
Remove Lower Guide
Upper and Lower Guides
and clean the point
path
Other
Contact a Fletcher-
Terry Customer Care
Representative at
800.843.3826