30
Method 3:
If the method 1 and method 2 operations are ineffective, please replace the nozzle
assembly. Click the [Maintain (Maintenance)]-[How to replace the nozzle?], and
operate following the instructions on the screen. That is, as follows:
Generally, users do not need to operate this. When the flatness of the equipment
that has undergone some calibration or the automatic leveling compensation is
still incorrect, it may be that the flatness of the platform has been damaged during
installation. At this time, the initial platform leveling is required.
7.2.3 Platform Flatness Calibration
1.
2.
Remove the flexible steel plate;
Loosen (note that the screws only
need to be loosened, and do not
need to be removed) the four locking
screws on the platform;
For this operation, you can contact Flashforge after-sales
personnel for remote assistance in the calibration.
Special note
After checking the steps shown on the screen, power off the
equipment before replacing the nozzle assembly.
Please operate as follows: There are 4 leveling points in total.
ATTENTION