Alarm Menu (continued)
Alarm Menu Organization
24
© 2011 Flanders Scientific, Inc.
Alarm Menu Functions (continued)
Remote Alarm Monitoring
When set to ON allows for remote alarm monitoring via FSI’s remote alarm monitoring software.
IRE Trigger Level
Sets the luminance threshold at which IRE alarms will be triggered, adjustable from 90 to 109 IRE
Audio Trigger Time
Sets the amount of time with mute audio that should elapse before the mute audio alarm is triggered.
Select Alarm Area
The screen area monitored for Alarm Triggers can be adjusted using the Select Alarm Area feature. To set
the alarm area simply highlight Select Alarm Area and press enter. Once active you can use the monitor’s
rotary knobs to adjust 4 lines on screen, similar to the custom graticules feature on the marker menu, to de-
fine the onscreen area that will be monitored. Once your desired area has been set simply use the Menu but-
ton to back out of the Select Alarm Area function. The default alarm monitoring area is the whole screen, but
this function allows users to specify smaller regions if only a portion of the screen area needs to be moni-
tored.
UMD Display
Only applies to Safety Broadcast Feature. Allows you to select whether the Source ID overlay displayed is
based on the manually set source ID on the monitor’s OSD menu or based on remotely set UMD information
over RS232 or RS422. You may also turn the selection to off to remove the Source ID overlay.
UMD Color
Only applies to Safety Broadcast Feature. Toggles the Source ID text color between White and Black.
UMD Position
Only applies to Safety Broadcast Feature. Select top or bottom of screen. Please note that when Timecode
Overlay is active the UMD will automatically be positioned at the bottom of the screen.
Audio Meter
Only applies to Safety Broadcast Feature. Determines position of 2 channel audio level meters. Select from
Horizontal or Vertical.
RS422 Address
Sets the monitors RS422 address for remote control and alarm monitoring. Set between 0~126.
Back to Table of Contents
Main Menu
Function
Alarm
Off
Scopes & VU-Meters
Visual Alarm
Off
Video
Remote Alarm Monitoring
Off
Audio
IRE Trigger Level
940
Marker
Audio Trigger Time
5s
System
UMD Display
Source ID
Alarm
UMD Color
White
OSD
UMD Position
Bottom
GPI
Audio Meter
Vertical
Display Alignment
Select Alarm Area
System Status
RS422 Address
1
Support
Baud Rate
9600.00
Parity
None
Alarm