Flanders Scientific LM-0750W Скачать руководство пользователя страница 22

  

 

System Menu (continued) 

System Menu Organization

 

22 

© 2011 Flanders Scientific, Inc. 

Back to Table of Contents

 

Main Menu

Function

DVI Selection

DVI-D

Scopes & VU-Meters

DVI Pixel Format

Full RGB

Video

Component Input

COMPONENT

Audio

Component Pixel Format

YPbPr

Marker

3G Level B

Stream 1

System

Back Light

35

Alarm

Back Light Interval

On

OSD

LED Light

On

GPI

Zoom

Keypad

Display Alignment

Language

English

System Status

Part Display

Off

Support

Load Profile

Default

Save Profile

Profile 1

System

System Menu Functions (continued) 

 

Back Light

 

This option allows you to set the Backlight setting (15~100) to adjust peak white luminance level. 

 

Back Light Interval

 

The backlight interval is a power saving feature; It allows you to specify the amount of time without an active 
signal being shown on the monitor that should be allowed to expire before the monitor’s backlight is turned off 
to reduce the power consumption of the unit.  When placed in the On position the monitor will not enter the 
power saving mode and will keep the backlight on so long as the monitor is left on. 

 

LED Light

 

Allows you to turn off the LED lights on the Monitor’s Keypad. 

 

Zoom

 

This allows you to specify whether the Zoom function is controlled by GPI remote control or via the keypad 
using an assigned function key.  The Zoom function zooms in on the incoming source until the entire screen 
is filled.  This is strictly a zooming function and does not alter the native aspect ratio of the source to fill the 
screen.  When viewing a 4:3 source in Zoom mode on a 16:9 display the aspect ratio of the visible video will 
remain 4:3 though the entire 16:9 screen will be filled.  Essentially the Zoom mode results in viewing a 16:9 
section of the 4:3 source and is most useful when viewing a letterboxed SD source on a widescreen display 
so that the most or all of the letterboxing is not shown, and only the video within the letterboxing is present. 

 

Part Display

 

Toggles whether just the center part (On) or entire source (Off) is shown in Sub Window Mode. 

 

Load Profile

 

Recall Saved Profile Settings.  Highlight desired profile & press ENTER to activate the saved profile selection. 

 

Save Profile

 

Saves all current monitor settings under a recallable profile by highlighting Profile number & pressing ENTER. 

Содержание LM-0750W

Страница 1: ...470 Satellite Blvd NE Suite P Suwanee GA 30024 Phone 678 835 4934 Fax 678 804 1882 E Mail Support FlandersScientific com www FlandersScientific com Click Here to Open Print Friendly Version of this Document Many of the topics covered in this manual are also covered by our Video Manual available at www FlandersScientific com This manual is based on firmware version 9 41 1710 If you have an older or...

Страница 2: ...Status 7 Function Menu 8 13 Marker Menu 14 Video Menu 15 17 Scopes VU Meters Menu 18 20 System Menu 21 22 Alarm Menu 23 25 OSD Menu 26 GPI Menu 27 Audio Menu 28 Display Alignment Menu 29 Monitor Specifications 30 Monitor Diagram LM 0750W 31 Monitor Diagram LM 1760W 32 Monitor Diagram LM 1770W 33 Monitor Diagram LM 2461W 34 ...

Страница 3: ...ed to rain or water When the product does not operate properly as described in the instruction manual When the product has been dropped or damaged When the product displays any abnormal operating condition If the product requires replacement parts make sure that the service person uses replacement parts speci fied by the manufacturer or those equivalent parts having the same characteristics and pe...

Страница 4: ...losed space make sure to provide proper ventilation to maintain allowable operating temperature range The LCD panel used in this product contains glass and can cause serious injury if broken If the unit is dropped or otherwise damaged take care to avoid possible injury by glass shards Keep this product away from heat generating sources such as radiators heaters stoves or other heat gener ating pro...

Страница 5: ... key s function is selectable form the Function Menu F4 assignable function key This key s function is selectable form the Function Menu F5 assignable function key This key s function is selectable form the Function Menu Menu Used to enable on screen menu Up Used in combination with Down and Enter Keys to navigate On Screen Menu Down Used in combination with Up and Enter Keys to navigate On Screen...

Страница 6: ... GPI General Purpose Interface for Contact Closure Remote Control Remote Control Functions can be assigned from Monitor Main Menu RS 485 RS 485 Ports In Out for looping remote control interface DVI I DVI I Input Supports both DVI Analog DVI Digital Analog Digital Toggle is found within On Screen Menu Video In Out Composite Video Input Loop Through Component In Out Component Video SD HD autosensing...

Страница 7: ...ory does not contain any configurable settings but does provide important information regarding your monitor s serial number firmware version current configuration 7 2011 Flanders Scientific Inc Back to Table of Contents Main Menu Function Function 1 Scopes VU Meters 1 Scopes VU Meters Function 2 Scopes VU Meters 2 Video Function 3 Scopes VU Meters 3 Audio Function 4 Marker Marker Function 5 Measu...

Страница 8: ...on toggles on off the onscreen display of a graphical cross hatch overlay Blue Only This function activates the monitor s Blue Only mode Marker 1 2 3 These functions activate the onscreen display of the preset Area Safety Custom Graticules or Active Boundary Markers as set in the Marker Profiles Marker presets can be customized via the Marker menu By utilizing this function you can toggle on off y...

Страница 9: ...t and provides an excel lent quality large scale representation of the SD source Full Screen Mapping The full screen mode will scale the incoming source to fill as much of the screen as possible while preserving the incoming source s native aspect ratio If the incoming source and panel share the same resolution then there will be no difference between 1 1 pixel mapping and full screen pix el mappi...

Страница 10: ... formats A Flashing Tally light will be activated on your monitor whenever you are in a zoomed mode as a reminder warning that the entire incoming signal is not being shown on the monitor To exit the zoomed mode simply press down on the REF POS rotary knob once more To exit the Pixel Zoom feature entirely simply press the function button assigned to this feature once more LUM Coloring This functio...

Страница 11: ...ge G Green level expressed as percentage B Blue level expressed as percentage R Red level as an absolute value between 0 255 for 8 bit and 0 1023 for 10 bit G Green level as an absolute value between 0 255 for 8 bit and 0 1023 for 10 bit B Blue level as an absolute value between 0 255 for 8 bit and 0 1023 for 10 bit You can also press the REF POS rotary knob F D BRIGHT Ref Pos to set a reference p...

Страница 12: ...re for an added level of detail If possible turn off any graphic overlays generated by the camera in use as these will register as very sharp in focus areas on screen and generate false focus level indications Level B Variable Wipe When monitoring a Level B 3Gbps SDI signal monitor must have 3Gbps SDI Input comprised of two multi plexed 1 5Gbps HD SDI signals the monitor will allow you to view the...

Страница 13: ... audio level meters En hanced Source ID display large overlay remotely or manually set Enhanced Alarm Window Display large window red background and enhanced timecode display large timecode overlay window Please note that as with the standard Alarm Monitoring feature the monitor may respond slowly to user toggles inputs if a constant alarm condition is occurring Toggles for UMD Display Color and P...

Страница 14: ...Background function can be used to toggle how the area that lies outside of the Area Marker or Safety Marker boundaries is represented You can select from normal which does not alter the outlying area Transparent which shades the outlying area with a translucent cast or Solid which mattes out the outlying area with your selected marker color Center Marker Toggles whether the center marker crosshai...

Страница 15: ...ult setting Please note that in DCI P3 mode the monitor will override this manual setting Attempting to select a Color Temperature setting manually with DCI P3 mode active will result in the monitor exiting DCI P3 color space mode Sharpness Level This function is a peaking level adjustment and produces an effect very similar to a physical aperture adjust ment By adjusting sharpness lower the image...

Страница 16: ... video can be displayed on screen With overscan On a small percentage of the outermost active video will not be displayed Additionally the monitor can scale the over scanned video full screen or blackout the outlying area while maintaining a pixel to pixel display of the video inside the active scan area To toggle between these variations of Overscan use the 1 1 Pixel to Pixel map ping function se...

Страница 17: ...ensate appropriately for differences in saturation and setup defaults within these standards Please note that you can override the setup selection set by this Component Setup feature by toggling the Composite Setup function after selecting the desired Component Setup default SDI Format ONLY APPLIES TO 3Gbps SDI ENABLED MONITORS FSI Monitors are capable of detecting the payload ID contained in an S...

Страница 18: ...aying two Scope Windows at the same time will cause the Scopes to update more slowly than displaying just one Scope Window To display just one scope Window select OFF in the secondary window selection An additional audio level meter mode called horizon tal audio level meter is also selectable This mode displays VU meters horizontally across the top of the screen but cannot be used in conjunction w...

Страница 19: ...ganized in groups the channels will be arranged with all channels of an Audio Group displayed on the same side of the screen to gether Audio Display Channels Allows you to select the Audio Level Meters Channels that will be shown on the Vertical or Horizontal Audio Level Meters Select from Channels 1 2 1 8 9 16 or 1 16 Permitted Max Level Allows you to specify the Max Audio Level for your onscreen...

Страница 20: ...e Scope Modes 20 2011 Flanders Scientific Inc Back to Table of Contents Luminance Vector Scope RGB Parade GBR Parade Color Histogram YCbCr RGB Histogram Column YRGB Peak Histogram RGB Overlay YCbCr Overlay Audio Phase Meter Audio Level Meters ...

Страница 21: ... 235 or YCbCr modes Component Input Component Pixel Format Use Component Input to toggle between Component Composite Video on LM 0750W s shared analog in puts Use Component Pixel Format to toggle the Analog Component Video Inputs between YPbPr or RGB mode 3G Level B When monitoring a 3Gbps SDI Level B signal monitor must be equipped with 3Gbps SDI Inputs compromised of two distinct 1 5Gbps HD SDI ...

Страница 22: ...ght on so long as the monitor is left on LED Light Allows you to turn off the LED lights on the Monitor s Keypad Zoom This allows you to specify whether the Zoom function is controlled by GPI remote control or via the keypad using an assigned function key The Zoom function zooms in on the incoming source until the entire screen is filled This is strictly a zooming function and does not alter the n...

Страница 23: ...time specified in the Au dio Trigger Time setting The audio mute alarm will only trigger if audio is being embedded into the signal and is mute for the specified amount of time there will be no audio mute warning if audio is not being embedded into the SDI signal Safety Video Alarm Same as Safety Alarm minus audio alarms IRE Alarm Will trigger an alarm if the IRE level specified in the IRE Trigger...

Страница 24: ...reen area needs to be moni tored UMD Display Only applies to Safety Broadcast Feature Allows you to select whether the Source ID overlay displayed is based on the manually set source ID on the monitor s OSD menu or based on remotely set UMD information over RS232 or RS422 You may also turn the selection to off to remove the Source ID overlay UMD Color Only applies to Safety Broadcast Feature Toggl...

Страница 25: ...is should be left at the default None position unless otherwise speci fied by Flanders Scientific s support department Back to Table of Contents Main Menu Function Alarm Off Scopes VU Meters Visual Alarm Off Video Remote Alarm Monitoring Off Audio IRE Trigger Level 940 Marker Audio Trigger Time 5s System UMD Display Source ID Alarm UMD Color White OSD UMD Position Bottom GPI Audio Meter Vertical D...

Страница 26: ...ume Contrast etc during adjustment Select from Top Center or Bottom Source ID Allows you toggle source ID function on off The Source ID function can be used to set a manual onscreen label of up to 5 characters This is often used to allow for the labeling of a monitor as PGM PVM CAM etc without using placards or tape Source ID Position Changes position of onscreen Source ID function Source ID Chara...

Страница 27: ...always the ground The GPI numbering on the GPI menu corresponds to the physical Pin assignments as follows Menu RJ 45 Pin GPI1 Pin 1 GPI2 Pin 2 GPI3 Pin 3 GPI4 Pin 4 GPI5 Pin 6 GPI6 Pin 7 GPI7 Pin 8 To prevent conflicts between menu toggles and GPI commands some features such as the marker selection toggle must be set to GPI in their respective menus i e Marker Menu in order to function properly I...

Страница 28: ...to select between Analog Audio input via minijack connector or No Sound when Component Vid eo is the selected video input CVBS Audio Allows you to select between Analog Audio input via minijack connector or No Sound when Composite Vid eo is the selected video input DVI D Audio Allows you to select between Analog Audio input via minijack connector or No Sound when DVI Digital is the selected video ...

Страница 29: ...e Field for Gain adjustment and a 30 to 40IRE grey field for Bias adjustment Color Space LM 2450W LM 2460W LM 2461W LM 2470W only The LM 2450W LM 2460W LM 2461W LM 2470W are wide gamut LCD monitors with the ability to work in several different color spaces Select from available option to instantly change the active color space Video Clipping Setting Video Clipping to On will clip all levels exceed...

Страница 30: ...Monitor Specifications 30 2011 Flanders Scientific Inc Back to Table of Contents ...

Страница 31: ...Monitor Diagrams 31 2011 Flanders Scientific Inc LM 0750W Back to Table of Contents ...

Страница 32: ...Monitor Diagrams 32 2011 Flanders Scientific Inc LM 1760W LM 1760WF Back to Table of Contents Without Stand With Basic Desktop Stand ...

Страница 33: ...Monitor Diagrams 33 2011 Flanders Scientific Inc LM 1770W Back to Table of Contents Without Stand With Basic Desktop Stand ...

Страница 34: ...Monitor Diagrams 34 2011 Flanders Scientific Inc LM 2450W LM 2460W LM 2461W and LM 2470W Back to Table of Contents Without Stand With Basic Desktop Stand ...

Отзывы: