Service Manual 599337A: 302B Series Titan Oven
July 2006
37
5.17 SYMPTOM: Fault Code F5 displayed
CAUSE:
A communications error occurred between the clock module and the power module.
DIAGNOSIS:
Check the connections between the power module and clock module.
If the fault code re-occurs, replace the power module. (refer to Servicing Instructions
Section 7.9)
5.18 SYMPTOM: Fault Code F7 displayed
CAUSE:
A fault occurred with the oven door lock.
DIAGNOSIS:
Check that the oven door lock has not jammed. (refer to Servicing Instructions
Section 7.24)
Check for oven door switch and door lock switch faults. (refer to Section 5.25)
Check for temperature sensor faults. (refer to section 5.23)
Replace the power module if no other component faults can be found. (refer to
Servicing Instructions Section 7.9)
5.19 Tracing Cooling Fan Faults
(Refer to Technical Overview Section 2.8)
PROCEDURE:
If the cooling fan will not start
1. Enter Technician Mode diagnostics to test the cooling fan operation. (refer to
Diagnostics Section 4.3)
The cooling fan will operate at low speed in normal operation. When the cooling
fan is turned on in diagnostics it will run at high speed.
2. Test for the correct voltage across the cooling fan contacts or substitute the fan with a
dummy load. Replace the fan if tests are good. (refer to Servicing Instructions
Section 7.16)
3. Check the fan wiring continuity back to the power module.
If the wiring continuity is good then it is likely that the cooling fan is not faulty.
(refer to Symptom Procedure Checklist for further component tests)
If the cooling fan will not turn off
1. Check for temperature sensor faults. (refer to Section 5.23)
The cooling fan will operate at low speed until the cavity temperature is below
300°F (150°C). If the cavity temperature is above 520°F (270°C) the cooling fan
will operate at high speed.
2. Replace the power module if no other component faults can be found, the cooling fan
triac may be faulty. (refer to Servicing Instructions Section 7.9)
Содержание Titan AeroTech OD302-B
Страница 1: ...Model OD302 B Model OS302 B Service Version B USA CANADA 599337A...
Страница 2: ......
Страница 44: ...Service Manual 599337A 302B Series Titan Oven July 2006 44 6 2 Single Oven USA Wiring Schematic...
Страница 50: ...Service Manual 599337A 302B Series Titan Oven July 2006 50 Figure 7 9c Figure 7 9d...
Страница 64: ...Service Manual 599337A 302B Series Titan Oven July 2006 64 8 N O T E S...