517804 D
38
•
Fit duct insulation and duct cover
•
Fit PC sensor into PC cover.
•
Replace shelves and crisper.
•
Turn water on and flush out system until all the air has been removed from water tank (refer
Diagram F).
Diagram F
Note: When replacing door ensure the collets are refitted and the product is water tested after
completion of repair.
9.10
Replacement of PC Door (Manufactured after May 2007)
1.
Disconnect the refrigerator from the power supply.
2.
Remove the top hinge cover to expose the wiring and water tubing.
3.
Disconnect the edge connector.
4.
Remove the left hand collet locking clip from the John Guest Fitting. (Refer Photo 0)
Collet Locking clips in
position – remove left hand
clip to remove door.
5.
Once the clip has been removed, push the collar in to remove the water tube.
6.
Remove the top hinge cover and hinge.
7.
Remove the water tube and wiring from the guide.
8.
Remove the door.
New PC sensor position