517804 D
36
Step 4
Refit in reverse order.
Ensure the wiring is placed and clipped into the
correct position.
Ensure the flow meter and water hose are in the
correct position prior to clipping the panel into
position.
If necessary, replace the water hose between the
flow meter and the dispenser.
9.7
Water Dispenser Pad Replacement
•
Remove the module (refer to Section 8.1.6).
To remove the pad, lift the sensor pad upward.
To refit the sensor pad, ensure the retaining clip
is as shown.
Refit in reverse to above procedure.
9.8
Removing Water Tank
•
Turn the water off at source.
•
Remove all shelves.
•
Remove the PC duct cover and PC Sensor from duct cover
•
Unclip the water reservoir cover from the cabinet liner.
•
The reservoir is removed by sliding a flat bladed plastic putty knife or spatula on top of the tank,
and with a folding motion of the spatula, lever the tank lip from the LH side to the RH side until clip
is lifted from liner and the tank is removed.
Diagram A
– tank in position
Diagram B
Fit spatula on the
RH side of lip and move to RH
side until unclipped.
Diagram A
Diagram B