1. Panda xControl Safety Instructions

1.1

Personnel

The settings described here can be performed by the operator unless highlighted differently.

The installation should be implemented by specially trained technical personnel or by authorised workshops (Fischer
Panda Service Points), only.

1.2

Safety instructions

Note!

Adhere to the safety instructions in the Fischer Panda 
generator manual. 

If these instructions are not to hand, they can be requested 
from Fischer Panda GmbH, 33104 Paderborn, Germany.

WARNING: Automatic start-up

An external signal may trigger an automatic start-up.

Warning!

The generator must not be operated with the cover 
removed.

If the generator is being installed without a sound insulation 
capsule, it must be ensured that all rotating parts (belt pulley, 
belts etc.) are covered and protected so that there is no 
danger to life and body!

All service, maintenance, or repair work may only be carried 
out when the unit is not running.

WARNING: Electrical voltage

Electric voltage - Deadly Danger!

Electric voltages of more than 48 V are potentially lethal in 
any situation. The rules of the respective regional authority 
must be adhered to for installation and maintenance.

For safety reasons, only an electrician may carry out the 
installation of the electrical connections of the generator.

Attention!

Disconnect battery before working on the generator

The battery must always be disconnected (first the negative 
terminal, then the positive terminal) if work on the generator 
or electrical system is to be performed, so that the generator 
cannot be started inadvertently.

This applies in particular to systems with an automatic start-
up function. The automatic start-up function shall be 
deactivated before starting work.

The flooding valve must be closed. (For PMS version only.)

Содержание xControl CB-G

Страница 1: ...Panda_xControl_eng R02 29 9 16 Panda xControl Manual...

Страница 2: ...the permission of the manufacturer Fischer Panda GmbH 33104 Paderborn reserves all rights regarding text and graphics in this document Details are given to the best of our knowledge No liability is a...

Страница 3: ...ting the illumination of the CP G 17 2 5 2 2 Setting the contrast of the CP G 18 2 5 2 3 Setting the standby time of the CP G 18 2 5 2 4 Setting the standby illumination of the CP G 18 2 5 2 5 Setting...

Страница 4: ...ls and messages on the display 25 2 6 1 1 Example of message Sensor defective 25 2 6 1 2 Example of message Sensor Cable break 25 2 6 2 Error code 25 2 6 2 1 Table of Faults 26 2 6 2 2 Description of...

Страница 5: ...ll rotating parts belt pulley belts etc are covered and protected so that there is no danger to life and body All service maintenance or repair work may only be carried out when the unit is not runnin...

Страница 6: ...Panda xControl Safety Instructions Page 6 Chapter 1 Panda xControl Safety Instructions 29 9 16 Note Also observe the safety instructions for the other components of your system...

Страница 7: ...led in the generator capsule The xControl GC S takes over the monitoring and control of the diesel engine of the Fischer Panda generator as well as the control of the output voltage and frequency of t...

Страница 8: ...Installation of the Connection Box xControl CB G The connection box is pre installed External components are connected in accordance with the installation manual and the circuit diagram of the xContr...

Страница 9: ...the generator Press the ON OFF switch to switch on the control system of the generator The xControl Generator thereby switches to standby mode If automatic starting is activated at the menu the gener...

Страница 10: ...up the starter battery must be disconnected before work on the generator may commence The Autostart also remains active if the xControl CP G is switched off and then on again If a fault should arise...

Страница 11: ...ame in all languages Fig 2 3 3 2 Overview Page 2 Symbols English Overview Page 2 Generator 06 Output voltage V 07 Generator current A 08 Generator apparent power kVA Note In the case of three phase ge...

Страница 12: ...ature of the generator winding 14 Temperature at exhaust manifold Note If the information pages of optional components e g fuel gauge oil pressure are available then these pages are inserted after Ove...

Страница 13: ...d residue this increases wear on the impeller 5 Visual inspection Control fixing bolts check hose connectors for leaks check electrical connections Check electrical lines for damage chafing 6 Switch o...

Страница 14: ...1 Switch on the panel 1 Switch on the xControl CP G The remote control panel is started by pressing the On Off button The On Off button must be pressed until the Home page is displayed Fig 2 4 3 2 St...

Страница 15: ...valve must definitely be shut while the attempts are being made The cooling water impeller turns during the starting process and feeds cooling water As long as the engine has not started up the exhau...

Страница 16: ...down to Enter Menu Page Press the Start Stop Enter key to enter the menu 2 5 1 Main Menu Fig 2 5 1 1 Main Menu You can choose from the following sub menus in the main menu 1 Panel sub menu The display...

Страница 17: ...y mode of the overview pages 6 Language selection changes the language of the panel 7 Temperature Unit to set the temperature unit to C or F 8 Audible alarm to activate the audible alarm in the event...

Страница 18: ...tem is selected by using the Step up Step down keys confirmed with the Start Stop Enter key The respective menu item opens Fig 2 5 2 3 1 Sub menu Standby Time The value is changed by using the Step up...

Страница 19: ...ng the Step up Step down keys and then confirm with the Start Stop Enter key Cancel or Confirm can be selected by using the Step up Step down keys and then confirmed with the Start Stop Enter key 2 5...

Страница 20: ...nd then confirmed with the Start Stop Enter key The Back item returns you to the Panel sub menu Cancel or Confirm can be selected by using the Step up Step down keys and then confirmed with the Start...

Страница 21: ...down keys confirmed with the Start Stop Enter key The respective menu item opens Fig 2 5 2 12 1 Resetting all values Cancel or Confirm can be selected by using the Step up Step down keys and then con...

Страница 22: ...anged by using the Step up Step down keys and the setting is confirmed with the Start Stop Enter key Cancel or Confirm can be selected by using the Step up Step down keys and then confirmed with the S...

Страница 23: ...r key Fig 2 5 3 2 2 Sub menu Operating Mode Setting the Operating Mode for the opt DC Output DP of the CP G An option can be selected by using the Step up Step down keys and the setting is confirmed w...

Страница 24: ...Step up Step down keys and then return to the Generator menu with the Start Stop Enter key 2 5 3 5 Resetting all values of the Generator sub menu to the default values The menu item is selected by us...

Страница 25: ...e Start Stop Enter key 10 Scroll down to the Confirm menu item and press the Start Stop Enter key The menu text is now set to the selected language 2 6 Faults 2 6 1 Symbols and messages on the display...

Страница 26: ...ltage Battery voltage too low yes yes 26 RPM failure RPM out of range Failure fuel supply Fuel empty n a yes 29 Power out relay Failure power out relay Short circuit n a n a 30 AC Voltage L2 Voltage t...

Страница 27: ...a 126 Temperature Fuel Fuel Temperature too high yes n a 130 No Panel found Wrong patch cable wrong contact check cable harness n a yes n a 131 Communication FP BUS Communication failure lost communic...

Страница 28: ...roken Short circuit Load OK Generator runs AC Voltage Generator off Run up phase Over ride Generator start up Temperature Standby Engine Automatic start up Exhaust system Starter battery Winding Opera...

Страница 29: ...hapter 2 Panda xControl Page 29 Fig 2 7 2 Terminating resistor 34 02 02 133H Terminating resistor 34 02 02 133H Fig 2 7 3 Adapter Frame 31 03 20 263H Adapter Frame 31 03 20 263H xContol CP G in a Gene...

Страница 30: ...Panda xControl Page 30 Chapter 2 Panda xControl 29 9 16 2 7 1 Dimensional drawing Fig 2 7 1 1 CP G...