General operation
Seite/Page 140 - Kaptitel/Chapter 13: General operation
14.7.16
.
Warning!: Automatic start-up
The autostart function will remain active even after the
controller is switched off and on again with the On/Off
button. To deactivate the autostart function, the flag in
the EEPROM must be reset with "Disable". Siehe
“Activating/deactivating the autostart function
("Autostart")” auf Seite 143.
Note: Manual start in autostart mode
If the generator is manually started up and stopped while
in automatic start-up mode, it will switch to stand-by
mode for safety reasons.
If necessary, the autostart mode must be reactivated.