14.7.16
13.2 Starting preparation / Checks (daily)
13.2.1 Marine version
1. Oil level control (ideal level: 2/3 MAX).
The level should be about 2/3 of the maximum level of a cold engine.
Further, if installed, the oil level of the oil-cooled bearing must be controlled before each start - see sediment bowl
at generator front cover!.
2. State of cooling water.
The external expansion tank should be filled up to 1/3 of the maximum in a cold state. It is very important that a
large expansion area remains above the cooling water level.
3. Check if sea cock for cooling water intake is open.
For safety reasons, the sea cock must be closed after the generator has been switched off. It should be re-
opened before starting the generator.
4. Check raw water filter.
The raw water filter must be regularly checked and cleaned. The impeller fatigue increases, if residual affects the
raw water intake.
5. Visual inspection.
Control fixing bolts, check hose connectors for leakages, control electrical connections.
6. Switch off the load.
The generator should only be started without load.
7. Open fuel valve, if installed.
8. Close battery main switch (on).
13.2.2 Vehicle version
1. Oil level control (ideal level: 2/3 MAX).
The level should be about 2/3 of the maximum level of a cold engine.
Further, if installed, the oil level of the oil-cooled bearing must be controlled before each start - see sediment bowl
at generator front cover!.
2. State of cooling water.
The external expansion tank should be filled up to 1/3 of the maximum in a cold state. It is very important that a
large expansion area remains above the cooling water level.
3. Visual inspection.
Control fixing bolts, check hose connectors for leakages, control electrical connections.
4. Switch off the load.
The generator should only be started without load.
5. Open fuel valve, if installed.
Close battery main switch (on).
Содержание Panda 5000i PMS
Страница 88: ...Maintenance Instructions Seite Page 88 Kaptitel Chapter 8 Maintenance Instructions 14 7 16 ...
Страница 94: ...Generator Tables Seite Page 94 Kaptitel Chapter 9 Generator Tables 14 7 16 Fig 9 8 1 Diamensions ...
Страница 102: ...Tables Seite Page 102 Kaptitel Chapter 10 Tables 14 7 16 ...
Страница 126: ...Inverter Panda PMGi Seite Page 126 Kaptitel Chapter 11 Inverter Panda PMGi 14 7 16 Leere Seite Intentionally blank ...
Страница 148: ...Seite Page 148 Kapitel Chapter 13 General operation 14 7 16 Leere Seite Intentionally blank General operation ...
Страница 158: ...Seite Page 158 Kapitel Chapter 15 Maintenance 14 7 16 Leere Seite Intentionally blank Maintenance ...
Страница 160: ...Seite Page 160 Kapitel Chapter 16 Annex 14 7 16 Leere Seite Intentionally blank Annex ...