29.12.04
DROP IN THE SPEED OF THE MOTOR
Cause
Solution
Too much oil.
Drain oil.
Too much oil.
Check fuel supply system:
• fuel filter, renew if necessary
• check fuel pump
• check fuel lines (bleed if necessary)
Lack of intake air.
Check air intake paths.
Check and clean air filter (and intake muffler if instal-
led).
Generator overloaded by too many load.
Reduce the electrical load (switch off load).
Generator overloaded by over-energizing.
Check that the proper capacitor type is installed and
that they are connected correctly.
Defective generator (windings, bearings, or other).
Generator must be sent to manufacturer for repair of
damaged bearings or winding.
Damaged engine.
Repair of bearing damage, etc., by Kubota-Service.
MOTOR SWITCHES ITSELF OFF
Cause
Solution
Fuel solenoid valve or throttle shut solenoid is not swit-
ching off.
Check wire connections to solenoid. Check valve
functions as in the "Inlet Fuel Solenoid Valve" or in the
trottle shut off solenoid sections. Replace if necessary.
MOTOR STOPS BY ITSELF
Cause
Solution
Lack of fuel.
Check fuel supply system.
Excess heat in cooling system (thermo switch tripped)-
lack of cooling water. Is indicated on the remote control
panel.
Check cooling water system flow: water pump, inlet
water filter, extra heat exchanger coolant flow.
Lack of oil (oil pressure sensor tripped).
Check oil-level and if necessary top up.
Check motor's oil-pressure and have repaired by
Kubota-Service if necessary.
Содержание AGT 4000 PVMV-N
Страница 36: ...The Panda Generator Page 30 Panda AGT DC 4000 PVMV N s00670 Chapter A The Panda Generator 29 12 04...
Страница 52: ...Maintenance Instructions Page 46 Panda AGT DC 4000 PVMV N s00670 Chapter C Maintenance Instructions 29 12 04...
Страница 64: ...Generator Failure Page 58 Panda AGT DC 4000 PVMV N s00670 Chapter D Generator Failure 29 12 04...
Страница 82: ...Installation Instructions Page 76 Panda AGT DC 4000 PVMV N s00670 Chapter E Installation Instructions 29 12 04...
Страница 90: ...Appendix Page VIII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...
Страница 93: ...Measurements 29 12 04 Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix Page XI F 6 Measurements...
Страница 94: ...Measurements Page XII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...