![Fischer Panda AGT 4000 PVMV-N Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/fischer-panda/agt-4000-pvmv-n/agt-4000-pvmv-n_handbook_2294280077.webp)
Installation Instructions
29.12.04
Panda AGT-DC 4000 PVMV-N s00670 - Chapter E: Installation Instructions Page 71
Discription of the illuminate diode (5) LED
all LED´s off
Generator is off
red LED illuminates constant
Generator is in „Stand-by“-mode
red LED blinks up to 20s
Generator is in start mode
red LED blinks more than 20s
Generator had not been started --> failure
green LED blinks
The genset had been startet on the panel with
6), runs, and can only be stopped by this but-
ton. (Even if there is a battery monitor instal-
led).
green LED illuminates constant
The generator had been external startet by an
extern switch. This could be the battery monitor
(terminal 13 and 14 on the panel) which will
start the generator after a adjusted time of one
minute if there is the voltage drops down in a
adjustable level, to reload the batteries.
On the panel at the terminal 15 and 16 is the
allocation for extern switches like thermo-,
time-, or ambient switches.
Every switch including the battery monitor will
overdrive each other. The shut down proce-
dure will works with the switch that had been
switched.
If there is no extern switch or battery monitor
allocated, this LED becomes not constant
flashing. (however green blinking)
If the external battery monitor is inbuilt to monitoring a battery-group, it will be advisable to switch
it with an accessory (On/Off) switch. This battery monitor ensures that he will be activ while the
voltage of the batteries is on the pre-set level. Therefore there is a time delay available the genset
will run until he reached the upper level. More information see battery monitor.
Содержание AGT 4000 PVMV-N
Страница 36: ...The Panda Generator Page 30 Panda AGT DC 4000 PVMV N s00670 Chapter A The Panda Generator 29 12 04...
Страница 52: ...Maintenance Instructions Page 46 Panda AGT DC 4000 PVMV N s00670 Chapter C Maintenance Instructions 29 12 04...
Страница 64: ...Generator Failure Page 58 Panda AGT DC 4000 PVMV N s00670 Chapter D Generator Failure 29 12 04...
Страница 82: ...Installation Instructions Page 76 Panda AGT DC 4000 PVMV N s00670 Chapter E Installation Instructions 29 12 04...
Страница 90: ...Appendix Page VIII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...
Страница 93: ...Measurements 29 12 04 Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix Page XI F 6 Measurements...
Страница 94: ...Measurements Page XII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...