Installation Instructions
Page 66 Panda AGT-DC 4000 PVMV-N s00670 - Chapter E: Installation Instructions
29.12.04
Time delay: 'td potentiometer'
This lower potentiometer adjusts the time delay in the sequence between the upper level being
reached (as set by the 'OFF potentiometer') and the actual signal to shut down the generator.
This time delay can be adjusted between 10 and 120 min. but can only be measured by timing
the actual delay.
Test button:
Underneath the extension terminals 1 - 2 is a hole which contains a switch that can be actuated
by a small screwdriver. You are able to simulate if the battery monitor will works correct even if
the voltage differences have been reached. This will be signaled by illumination of the LED. The
test could only be successfull if the extension terminals 1,2, 7 and 8 are being allocated.
Clamp
Function
Clamp
Function
1
Battery positive pole (+)
5
not allocated
2
Battery negative pol (-)
6
not allocated
3
measuring connection shut down
voltage
7
positive output of the sensor
4
measuring connection switch on
voltage
8
negative output of the sensor
Batteriewächter
E.3.1 Adjustments
01
03
05
02
04
01. Connections 1-8
02. Test button
03. Switch off potenttiometer
04. Switch on potentiometer
05. Time delay potentiometer
Содержание AGT 4000 PVMV-N
Страница 36: ...The Panda Generator Page 30 Panda AGT DC 4000 PVMV N s00670 Chapter A The Panda Generator 29 12 04...
Страница 52: ...Maintenance Instructions Page 46 Panda AGT DC 4000 PVMV N s00670 Chapter C Maintenance Instructions 29 12 04...
Страница 64: ...Generator Failure Page 58 Panda AGT DC 4000 PVMV N s00670 Chapter D Generator Failure 29 12 04...
Страница 82: ...Installation Instructions Page 76 Panda AGT DC 4000 PVMV N s00670 Chapter E Installation Instructions 29 12 04...
Страница 90: ...Appendix Page VIII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...
Страница 93: ...Measurements 29 12 04 Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix Page XI F 6 Measurements...
Страница 94: ...Measurements Page XII Panda AGT DC 4000 PVMV N s00670 Chapter F Appendix 29 12 04...