![Fischer Panda 0014668 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/fischer-panda/0014668/0014668_manual_2294271059.webp)
Installation Instructions
23.3.18
Kapitel/Chapter 5: Installation Instructions - Seite/Page 59
Fig. 5.8.0-1: Example for an unfavourable Installation
5.9
Fuel system installation
5.9.1 The following items need to be installed:
• Fuel supply pump (DC)
• Pre-filter with water separator (not part of the delivery)
• Fine particle fuel filter
• Return fuel line to fuel tank (unpressurized)
The external Fuel pump should be installed near the fuel tank
Fig. 5.9.1-1: electrical fuel pump
Electrical fuel pump
With the Fischer Panda generator is usually supplied an
external, electrical fuel pump (DC). The fuel pump must be
installed close at the fuel tank. The electrical connections is
prepared at the generator.
Some generators (f.e. with Deutz diesel engine) has an
engine driven internal fuel pump. At these generators the
electrical fuel pump is optional.
Example of an unfavourable installation:
- Water lock not far enough below the lowest level of the generator
- Distance water lock to gooseneck too large