Operators of the PBC 6000 system must be fully trained on the performance, operation,
adjustments and safety standards of this machine before attempting to operate it. Long hair must
be pulled back and tied to avoid getting caught in any moving parts of the system. Operators of this
machine must wear eye and foot protection at all times and gloves when working around the hot or
sharp machine surfaces. Operators must always wear proper eye protection when operating this
machine and not wear loose clothing or jewelry.
The surrounding area around the machine must be kept clear of objects and potential hazards so the
operator can have quick easy access to any part of the PBC. The PBC 6000 must never be
operated without all of its components. The covers, guides, guards and shrouds must be installed
on the machine when being operated. Only use the PBC 6000 for its intended use.
The PBC 6000 is equipped with a three position Motor Enabled Switch, located on the side of the
electrical enclosure. (
Illustration 8.5, page 28
) The “
AUTO
” position is used during normal
operation of the machine. The drive motor will only activate when the swing channel begins to
close. The “
STOP
” and “
RUN
” positions are provided
only
for technicians, to perform
maintenance on the machine. The “
STOP
”
position disables the drive motor, but will still
allow the pneumatic controls to work. The “
RUN
”
position is used to enable the drive motor only
when the machine is powered. This mode does
permit the drive motor to rotate, when the swing
channel is open.
6.2 ELECTRICAL
SYSTEM
The system is wired at the factory for the voltage
specified when ordered. Customers are required to
supply incoming electrical connections. SO 12/4
(12 AWG/4 wire) (4 mm
2
) is recommended.
CAUTION: Be sure machine is connected
to building electrical ground.
Follow
National Electrical Code (NEC) and all local
electrical codes during installation.
Note:
Electrical
schematics for each unit’s particular voltage option
are shipped inside the electrical connection box on
the back of the unit.
For load specifications refer to
TABLE 1 on page 8
.
While performing maintenance to the machine,
always turn “OFF” and lock out the electrical
supply. (
Illustration 6.1
) Operate the PBC 6000
with the designed electrical needs. The electrical system of the machine should never be altered.
Illustration 6.1
Содержание PBC-6000
Страница 69: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 72 this page left blank...
Страница 71: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 75 this page left blank...
Страница 73: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 78 this page left blank...
Страница 75: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 81 this page left blank...
Страница 77: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 84 this page left blank...
Страница 79: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 87 this page left blank...
Страница 81: ...FISCHBEIN Co MODEL PBC 6000 OPERATOR S MANUAL REV D 2005 03 90 this page left blank...