3-12
VAC:
(Thermister required) this determines the temperature at which the CM7 will provide an output
on any POC programmed with setting 22(VAC: Ventilation-Air Conditioning) which can be used to
vent widows, activate AC controls, or cooling seats.
FO1 - 100°F:
This option will provide a pulsed output on any POC programmed with setting 22
(VAC) if the temp sensor reads at or above 100°F with remote start confirmation.
FO2 - 90°F:
This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 90°F with remote start confirmation.
FO3 - 80°F:
This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 80°F with remote start confirmation.
FO4 - 90°F:
Latched output: this option will provide a latched output for the selected runtime on any
POC programmed with setting 22 (VAC) if the temp sensor reads at or above 90°F.
3-13
Defrost output Temperature Control:
This feature will determine the temperature at which the
CM7 will provide an output on any POC programmed with setting 17 or 21 (defrost and defrost 2).
FO1 - Standard:
(Default) this option will provide an output (length of output based on feature
3-13 option settings) on any POC programmed with setting 17 (defrost) or 21 (defrost 2) every time
with remote start confirmation.
FO2 - 32°F:
(Thermister required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 32°F. (Length of output based on feature 3-13 option settings)
FO3 - 42°F:
(Thermister required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 42°F. (Length of output based on feature 3-13 option settings)
3-14
Defrost output Timing:
This feature controls the output timing of POC setting 17, defrost.
Note:
POC setting 21 defrost 2 is has a fixed pulsed output and is NOT affected by this
feature.
FO1 - 500mS Pulse:
This option will provide a 500 Millisecond pulsed output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option setting.
FO2 - 3 minute latched:
This option will provide a 3 minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option setting. (This would
be good for any rear view mirror defrost that may need a short latched output time.)
FO3 - 7 minute latched:
This option will provide a 7 minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off of feature 3-12 option settings. (This
would be good for many front, rear, or rear view mirror defrost functions that may need a longer
latched output time.)
FO4 - Latched for entire runtime:
(Remote start runtime based off of feature 2-07 option
setting) This feature will provide a latched output for the entire remote start runtime on any POC
programmed with setting 17 (defrost) with timing based off of feature 3-12 option settings. Caution:
make sure not to latch rear defrost functions on for too long as it may cause damage to the heating
elements in the window.