2-04
Trigger Start:
This feature changes the number of pulsed inputs (min of 60mS per pulse) on the
trigger start input wire. (Pink wire CN5).
Note: If option 3 is selected and OEM remote
control feature is available through data, the Control Module will accept 3 OEM lock
commands to activate the start sequence.
FO1 - Off:
(default)
FO2 - Single pulse:
This option will trigger the remote start sequence with a single pulsed input to
the trigger start wire. This is ideal when adding accessories that can trigger the CM7.
FO3 - Double pulse:
This option will trigger the remote start sequence with 2 pulses to the trigger
start input wire. This can be used when integrating with an OEM keyless entry remote.
FO4 - Triple pulse:
This option will trigger the start sequence with 3 pulses to the trigger start input
wire. This is ideal when trying to integrate the OEM keyless entry remote. Note: this option will also
allow the CM7 to accept a 3 pulse input from OEM remote commands through data.
2-05 Cold or Hot Start:
Note: the Firstech Thermister temp sensor must be connected to the
CM7 in order to use these options.
This feature turns on the cold/hot Timer start features.
FO1 - Off:
(default)
FO2 - Cold start:
This option enables the thermister when using Timer Start Mode. It will start the
car at the preset cold temperature (see feature 2-08) according to the selected timer start option (see
feature 2-06)
FO3 - Hot Start:
This option enables the thermister when using Timer Start Mode. It will start the
car at the preset hot temperature (see feature 2-09) according to the selected timer start option. (see
feature 2-06)
FO4 - Cold And Hot start:
This option enables the thermister when using Timer Start Mode. It will
start the car at the preset Cold and Hot temperature (see features 2-08 and 2-09) according to the
selected timer start option (see feature 2-06)
2-06 Timer Start: This feature is designed to allow the user to have the CM7 automatically remote start
at the end of a selected timed cycle. It also be controlled by the thermister so it will start at a specified
temperature at the end of the timed cycle.
FO1 - 3 hour cycle:
(4 minute runtime, 8 minute runtime for diesel) Once Timer Mode is enabled
(see feature 2-13) the CM7 will wait 3 hours, remote start and run for 4 minutes unless the cold start
feature is enabled. If this is the case, the CM7 will check the temperature once every 3 hours. If it is
at or below the selected temperature, (see feature 2-08) it will start and run for 4 minutes. The same
procedure will apply to the hot start feature. If there is any interaction with the CM7 after timer mode
has been activated using the Firstech remote or accessory, timer mode will be cancelled and must be
re-started in order to start a new timed cycle.
FO2 - 2 hour repeat with cold starting:
(runtime based on feature 2-07 option setting and
cold start setting based on feature 2-08) Note: 2 way LCD remote required. This option is designed
to monitor the temperature 2 hrs. After timer mode is set and start if it is at or below the preset cold
start temperature (see feature 2-08). This process will continue until the user manually starts or remote
starts the vehicle.