This special option group allows you to determine the output type of the POC wire. For example, if you want
to set POC #5 (default setting status out) to Aux 1, you will need change special option 5 to number 10.
This must be done with the OP500.
POC 1 - Blue/White • GWA (starter interrupt/Anti-grind):
(default setting) This channel will
provide a 250mA (-) negative output when the CM7 is armed
(function also POC setting
18)
POC 2 - White • Horn:
(default setting) This channel will provide a 250mA output when Horn
is triggered.
(function also POC setting 8)
POC 3 - Blue/Black • Lock:
(default setting) This channel will provide a 250mA output with the
lock/arm command.
(function also POC setting 25)
POC 4 - Blue • Unlock:
(default setting) This channel will provide a 250mA output with the
unlock/disarm command.
(function also POC setting 26)
POC 5 - Orange/White • FAD (Factory Alarm Disarm):
(default setting) This channel will
provide a 250mA output with the unlock/disarm command.
Note: the CM7 will provide
this output approx. 100mS before the unlock output. (function also POC setting 7)
POC 6 - Orange • FAA (Factory Alarm Ream):
(default setting) This channel will provide a
250mA output with the lock/arm command. Note: the CM7 will provide this output approx.
100mS before the unlock output.
(function also POC setting 6)
POC 7 - Violet/White • Trunk release:
(default setting) This channel will provide a 250mA
output with the trunk release command.
(function also POC setting 28)
POC 8 - Black • GWR (ground when running aka status output):
(default setting) This
channel will provide a 250mA output with the remote start activation command and
continue to provide output until 100mS after the remote start process has shut own.
(function also POC setting 5)
POC setting value description (SV)
SV 1 -
Parking light:
provides a 250mA (-) negative parking light output on any POC programmed
with this setting.
SV 2 -
Starter:
provides a 250mA (-) negative starter output on any POC programmed with this
setting.
SV 3 -
Ignition:
provides a 250mA (-) negative ignition output on any POC programmed with this
setting.
SV 4 -
Accessory:
provides a 250mA (-) negative accessory output on any POC programmed with this
setting.
SV 5 -
GWR (status):
provides a 250mA (-) negative while remote started on any POC programmed
with this setting. Can be used to activate interface modules during the remote start process.
SV 6 -
FAA (Factory Alarm Arm):
provides a 250mA (-) negative output with the arm/lock command
on any POC programmed with this setting.
SV 7 -
FAD (Factory Alarm Disarm):
provides a 250mA (-) negative output with the disarm/unlock
command on any POC programmed with this setting.
SV 8 -
Horn:
provides a 250mA (-) negative output with output control based on feature 3-08 option
setting when using any POC programmed with this setting.
SV 9 -
Dome light supervision:
provides a 250mA (-) negative output with the disarm/unlock
command, on any POC programmed with this setting, for up to 45 seconds or until ignition is
on.
Copyright 2014 Firstech, LLC.
Page 3
Copyright 2014 Firstech, LLC.
Page 3
Copyright 2014 Firstech, LLC.
Page 46
CM7200
Master Guide
Starter System
techfeed.compustar.com