3-15
Soft Disarm:
this feature will enable Factory Alarm Arm (FAA) and Factory Alarm Disarm (FAD)
outputs to trigger when silencing the Compustar siren when sounding with full alarm.
FO1 - Off:
(Default) this will keep the standard Compustar soft disarm operation. Soft disarm feature
allows the user to silence the Compustar siren as its sounding with full alarm without fully disarming
the system which may unlock the doors and leave the vehicle unsecure.
FO2 - On:
this option will provide a FAD output on both data and analog connections, when the
user taps the unlock/disarm once to silence the Compustar system while it’s sounding, so it will disarm
any factory alarm that may be sounding as well. In case the FAD function unlocks the doors the CM7
will send the FAA on both data and analog connections 5 seconds later to make sure the vehicle is
re-locked and secure. (This feature works well with GM, Chrysler, Dodge, Jeep, Toyota, Lexus vehicles
that may have factory security.)
3-16
RPS:
(Remote Paging Sensor) this feature sets the RPS hardware being used with the CM7.
FO1 - RPS Touch:
(default) this option enables the RPS touch functions when using the RPS touch
hardware with the CM7. RPS can be used to arm/lock and disarm/unlock a CM7 or page a Firstech
remote or accessory. Please refer the RPS section of this manual or the RPS product manual for
installation and operation of the RPS touch hardware.
FO2 - RPS II:
(knock sensor) This option enables the RPS II functions when using the RPS II hardware
with the CM7. RPS can be used to arm/lock and disarm/unlock a CM7 or page a Firstech remote or
accessory. Please refer the RPS section of this manual or the RPS product manual for installation and
operation of the RPS II hardware.
4-01
Aux 1 Output:
This feature determines the duration of the auxiliary 1 output. (Option 4 allows the
output duration to be set for a specific length of time 1-99 sec. and 1-15 min (with OP500 update only)
(Specific time setting only available when using the OP500)
FO1 - 500mS:
This option will provide a (-) negative output for 500 milliseconds (Half second)
output on any POC programmed with setting 10 (AUX 1)
FO2 - Latched:
This option will provide a latched (-) negative output on any POC programmed with
setting 10 (AUX 1).
Note: This will stay latched until AUX 1 command is sent again to
shut it off.
FO3 - 500mS pulse + programmable timed output:
this option will provide a (-) negative
output for 500 milliseconds (0.5 seconds) output on any POC programmed with setting 10 (AUX
1). It will pause for 250 milliseconds then provide a timed output (based off of feature 4-01 option
4). Note: in order to program the timed output the user must change feature 4-01 to option 4, then
adjust AU1 (AUX programmable output time) to desired time. To complete the programming steps
feature 4-01 must be changed to option 3. I.e. 0.5 second pulse…pause…10 second pulse, this
option can be used to roll windows up or down on a vehicle that requires a similar action using the
driver’s door key cylinder.
FO4 - Program:
This option allow the AUX output time to be programmed for a duration between
1-99 seconds. Note: with an OP500 update there will be additional time duration between 1-15
minutes available.