![First Innov PRIMAPROTECT Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/first-innov/primaprotect/primaprotect_user-and-installation-notice_2293774019.webp)
User notice Primaprotect
version 1.0
19
7.1 Weak battery indicator of the posts
Fig 20 : LEDs “failure” of the master post. Fig 21 :LED “Weak battery” of the slave post
*Red Led blinks when a failure is detected on the card of the master post.
**Only accessories, bracelets or gate sensor
7.2 Weak battery indicator of the accessories
7.2.1 Weak battery of the remote of the keypad :
The LEDs of the remote and the keypad shut off when the batteries are weak.
7.2.2 Weak battery bracelet and gate sensor :
When the batteries of the bracelet or gate sensor are weak, the central emits a beep every
30 seconds and the LED « Failure » of the master post starts blinking.
To identify the failing bracelet or gate sensor, carry out the recognition procedure (§ 6.1)
for each accessory. If the recognition procedure is successful, the battery is still
operational. If the recognition systematically fails, the accessory with the weak battery has
been identified.
If the system continues to emit beeps, it means that another accessory has a weak
battery. In that case, repeat the identification procedure.
8 MAINTENANCE
It is advised to regularly test the proper operation of the Primaprotect alarm system.
Regularly clean the panes of the posts (Warning ! Do not use abrasive products).
Red LED :
9V battery weak
Red LED *
Orange LED : battery
accessories** weak
Red :battery 3V
weak
Red LED :
3V battery