User notice Primaprotect
version 1.0
10
When the batteries are plugged, the red LEDs of the receiving cells of each post light up.
Follow the procedure below:
1 – Remove any obstacle which might be in the way of the beams’ alignment.
2 – Start with the high beam F1 (see illustration 12)
3 – Make sure that the transmitting cell is properly oriented towards to the receiving cell
located at the same height.
-
When the receiving cell is properly aligned towards the transmitting cell, the
red LED of the receiving cell lights up continuously.
-
If the red LED of the receiving cell flashes, it means that it is not receiving the
IR beam. In that case, redirect the transmitting cell and then the receiving
cell as shown in the illustration 13 until the red LED lights up continuously.
4 –
Position the optical filter
on the receiving cell as indicated in illustration 13. The red
LED of the receiving cell must light up continuously. If it starts blinking, you need to
sharpen the alignment of the cells.
5 – Repeat the same procedure successively for each high beam F2, F3 and then F4. This
procedure must be carried out clockwise and the same way for the lower beams F5, F6,
F7 and finally F8.
At the end of this procedure, if the green LED of the master post (refer to illustration 3)
lights up continuously, the infrared beams are correctly aligned.
If the red LED of the master post lights up continuously, it means that at least one cell is
not properly aligned. In that case, you must start over the procedure.
Once the procedure is completed, position the magnetic key on the reference mark
“Activation / deactivation” of the post (see illustration 3). The system shuts itself down
temporarily (red LED starts blinking). Mount the post’s cover and the system is now
operational. If you encounter any difficulty, please refer to § 9.
WARNING :
A proper operation of your Primaprotect alarm system depends on the alignment of the
cells. The alignment procedure is mandatory when you first use the system. It must be
carried out on all the beams of the installed system. Do not use the remote or the bracelet
during the alignment procedure.
VERY IMPORTANT
:
The alarm system enters automatically into installation mode for
1h30mn after the batteries were plugged. This time is plenty enough for the installation of
your Kit Primaprotect. Passing this delay the LEDs of the cells turn themselves off and you
are no longer in “installation mode”.
If you have not finished the alignment procedure during the allocated time, you can re-
enter the installation mode by pushing the button on the card of the master post (see
illustration 19).
Содержание PRIMAPROTECT
Страница 14: ......