background image

11 

 

Tank Filling and Water Treatment

 

Operation Instructions

 

REQUIRED 

 

Funnel and Hose[15] 

a) 

Filling requires a large bucket (not supplied) and the 
supplied water Funnel and Hose[15]. Filling will take 
approximately 8 liters of water.

 

b) 

Open the yellow fill plug on the back of tank and insert 
hose (rotating the impeller slightly may be necessary 
to allow the hose to pass). In areas where tap water 
quality is known to be poor,  FD F  recommends the use 
of distilled water.

 

c) 

Move the tank adjuster handle to level 10 and begin 
filling. Do not fill the tank higher than the level         
indicator on the front of the clear shell.

  

d)  Once filling is complete follow the water treatment 

schedule below.

 

CAUTION

 

Use a drop cloth under 

the tank when filling to 

avoid damaging to floor or 

 

carpet. 

Do not fill past the 

   

calibration mark as 

   

indicated on the tank  

 

level sticker or water 

spillage may occur. 

WARNING

 

Impeller blades are sharp! 

Do not Place fingers in 

tank to adjust impeller po-

sition. 

It is recommended to use 

the end of the hose should 

the impeller require      

adjustment 

CAUTION

 

 In areas where tap water 

quality is known to be 

poor, FDF recommends 

the use of distilled water.  

INITIAL WATER TREATMENT

 

Add One Water Treatment Tablet  per full tank. Do NOT, UNDER ANY CIRCUMSTANCE, 

USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. 
Your unit purchase includes 4xWater Treatment Tablets, which  is sufficient for several 

years of use. 
To purchase additional Water Treatment Tablets, please consult your nearest regional 
dealer/distributor or check our website at www.firstdegreefitness.com

 

NOTE: For simple, fast and efficient filling and/or drainage of the Fluid Tank, we have a 

battery operated pump (rechargeable via USB) available as an option.  We recommend 
this to any commercial facility, with multiple units, that has a need to drain and refill 

Tanks from time to time.  To purchase, contact your nearest First Degree Fitness     
distributor or go to our website on www.firstdegreefitness.com for details.  

 

Water Funnel 

and Hose   

supplied with 
unit

  

Orange tank  

fill plug

 

Note:  

The lower 
tank plug is 
permanently 

sealed

 

Содержание Power Cube

Страница 1: ...USER GUIDE...

Страница 2: ...2...

Страница 3: ...meaning it has the capacity to perform many movements and mimic many patterns This is extremely beneficial in both rehabilitation and sports performance applications The bar attachment can be used to...

Страница 4: ...sembly 6 POWER CUBE Box Contents 7 Assembly Instructions 8 Operating Instructions 11 Bluetooth Auto Adjust Monitor 13 Calibration Procedure Power Zone UBE Series 14 Maintenance Troubleshooting 16 Inte...

Страница 5: ...and tear Should defective components be identified replace and or keep the unit out of use until it is repaired 4 Wear comfortable clothing that allows freedom of movement and shoes with non slip sole...

Страница 6: ...turn of a lever Product Highlights Ergonomic support bar for squat and lower extremity cable work Auto level Bluetooth monitor real time power in watts per repetition Accessories hip and squat belt s...

Страница 7: ...Frame 9 1 M10x60 Bolt 2 1 Handle Bar 10 7 M10 Washer 3 1 Accessory Rack 11 1 8mm Allen Key 4 1 Ankle Strap 12 2 D Cell Duracell Battery 5 1 Handle 13 1 Touch Up Paint 6 1 Squat Belt 14 4 Water Treatme...

Страница 8: ...ts against the box contents a Pull the Foot Plate into the vertical position b Put and insert the Foot Plate downward and make sure the bolt holes are aligned Secure the front of the Foot Plate using...

Страница 9: ...re the bottom of the Foot Plate using the 2x M10x15mm 7 and 2x M10Washers 10 and tighten securely Carefully stand the unit upright Secure both sides of the Foot Plate using the 4x M10x25mm Bolt 7 and...

Страница 10: ...kle Strap 4 Handle 5 Squat Belt 6 Install the Accessory Rack 3 using 4x M6x15mm Bolt 8 Torque 180 Kgf Cm 13 lbf ft 17 6Nm a Insert the Accessory Rack 3 into the Main Frame b Secure using 4x M6x15mm Bo...

Страница 11: ...mpeller po sition It is recommended to use the end of the hose should the impeller require adjustment CAUTION In areas where tap water quality is known to be poor FDF recommends the use of distilled w...

Страница 12: ...by these three factors load resistance range of motion ROM and rate speed Good form and patterning are essential to proper biomechanics in any movement A few key points to remember are a Weight evenly...

Страница 13: ...otentiometer automatically adjusts the computer s resistance level according to the position of the Fluid Force Lever on the tank BLUETOOTH CONNECTIVITY Each Rower is fitted with the most advanced con...

Страница 14: ...ay will show When into Calibration LEVEL will display 1 1 Turn the Adjuster Handle on the tank to LEVEL 1 2 Then press RESET Display will show 2 on the LEVEL which mean Calibration is complete for LEV...

Страница 15: ...er Handle on the tank to LEVEL 2 2 Then press RESET Display will show 3 on the LEVEL which mean Calibration is complete for LEVEL 2 2 Press RESET to complete the Calibration for LEVEL 2 Repeat STEP 2...

Страница 16: ...tic and illuminates but does not register with movement It is possible that there is a loose connection Check that the computer lead is connected properly to the unit If connected properly check senso...

Страница 17: ...re 2 Year Limited Warranty FIRST DEGREE FITNESS will repair or replace any component should it fail due to any defect in materials or workmanship within 2 years of the original purchase General Exclus...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 CONTACT US For customer support please visit firstdegreefitness com support TAIWAN T 886 3 478 3306 764 Chung Shan South Rd Yangmei Taoyuan Taiwan R O C...

Отзывы: