Firetide HotPoint 5200 Скачать руководство пользователя страница 25

19 

 

 

 
 
 
 

 

Weatherproof procedures

 

Cable connections become loose over time due to vibration. Loose connections 
let moisture contact and erode the interface to a connector. To avoid 
performance problems due to moisture damage, Firetide recommends that you 
use butyl mastic and electrical tape or silicone tape to make all outdoor 
connections  weatherproof. 
The next picture shows where the weatherproofing needs to go on a HotPoint 

5200 access point. 

 
 

 

Put  weatherproofing  where... 

-

 

lightning arrestor and mesh node meet 

-

 

lightning arrestor antenna cable meet 

 

 

 

Best practice: 

You can use colored tape for easy identification of the connectors 

from the mesh node to the antenna. 
Butyl mastic is a synthetic rubber sealant that you can use to make a connection 
weatherproof. It is slightly sticky and stays flexible; it bonds to itself to make a 
good seal. Butyl mastic and a layer of electrical tape keeps the cable assembly 
clean, dry, and easy to change in the future. 

Note: 

To make a strong watertight connection, keep a high level of tension in the 

butyl mastic when you stretch it over the cable and connector. 

Содержание HotPoint 5200

Страница 1: ...HotPointTM HardwareInstallationGuide HotPoint 5200 Access Point Published March 2014 Revised 2016 ...

Страница 2: ...iableconnectivityanywhere HotPort andHotPointareall trademarksofFiretide Inc Allothertrademarksarethepropertyoftheir respective owners Informationinthisdocumentissubjecttochangewithoutnotice Firetide Inc 2105S BascomAvenue Suite220 Campbell CA95008 USA www firetide com ...

Страница 3: ...gerof electrocutionisprobable Thisimageappearsbeforeeachelectrical hazard statement Warnings contain safety information that you must obey If you do notobeytheinstructioninawarning theresultmightincludeserious injuryordeath Thisimageappearsbeforeeachwarningstatement Cautions contain information that you should obey to avoid minor injury inconvenience anddamagetoequipment Thisimageappears beforeeac...

Страница 4: ...einformation Youmustalsohaveadministratoraccesstothemeshtobeabletoreceive technical support Thenexttableliststhecontactinformationforcustomersupport Worldwide customer support Days Hours Contact Americas Monday to Friday 7 00amto5 30pmPST Pacific standard time http www firetide com requestsupport 1 877 FIRETIDE extension 2 1 408 399 7771 extension2 1 408 355 7271 Africa Monday to Friday http www f...

Страница 5: ...ptional accessories 2 HotPoint 5200 access point setup 3 Verifyingtheboxcontents 3 PartsofaHotPointaccesspoint 3 Attachingcablesandconnectors 4 Connectingacomputertoanewaccesspoint 4 LEDs 7 LEDbootoperation 7 LEDoperationduringclientassociationand data traffic 7 LEDoperationduringafirmwareupgrade 7 Radios 7 Groundscrew 7 Outdoordeviceinstallation 9 Safeinstallationpractices 10 Preparing earth grou...

Страница 6: ...ennas for outdoor use 17 Attaching anantenna 17 Connecting antennas 18 Recommendations for indoor use 18 Recommendations for corrosive environments 18 Weatherproof procedures 19 Tools and materials to weatherproof connections 20 Makingaweatherproofantennaconnection 20 Makingaweatherproofcabletonodeconnection 22 Troubleshooting 25 Resettinganoutdoornodetofactorydefaultsettings25 Improvingclientexpe...

Страница 7: ...tsantennas isacompletesystemforwireless access service delivery ThenextfigureshowstheHotPoint5200accesspointcorrectlyorientedfor installation to a poleormast InlocationswhereaccesstoEthernetorpowerislimited theaccesspointcan receive Power over Ethernet PoE Caution A HotPort 7020 cannot supply power to a HotPoint 5200 access point TheHotPoint5200accesspointhasaUL2043plenum ratedenclosureandhas thes...

Страница 8: ...ew Pro HotViewProisarobustnetworkmanagementsoftware NMS Itletsyoumanage manyFiretidedevicesatthesametime TouseHotViewProyouneedtopurchase onemanagementlicenseforeachaccesspoint Optionalaccessories These accessories are available for purchase 2 4GHz 8dBiomni directional3x3MIMOantenna AO 024 MIMO 8 5GHz 8dBiomni directional3x3MIMOantenna A0 050 MIMO 9 LMR400cablewithlowlosslightningsuppressors 1 5ml...

Страница 9: ...ins these items OneHotPoint5200accesspoint Onepowercable USAtype OnePower over Ethernet PoE injector Sixdual band2 4GHzand5GHz 3dBiomni directionalstagingantennas SixSMAtotype Nplugadapters OneEthernetcable Onefield installableEthernetconnector Mount kit Quick Start Guide Ifanyoftheseitems ismissingfromthebox callyourresellerforhelp Parts of a HotPoint access point Thenextpictureshowstheradios LED...

Страница 10: ...OUTportofthePoEinjector AttachanotherEthernetcablefromtheadministrator scomputerto theINportofthePoEinjector Optional Attachthepowercabletoapowersource Connecting a computer to a newaccess point YouneedtochangetheTCP IP4settingsonyourcomputersothatyoucan communicatewiththeaccesspoint Thefirsttimeyouconnecttotheaccess point youneedtochangetheTCP IP4settingonyourcomputer Note IfyouareusingPoE connec...

Страница 11: ...are Installation Guide 5 Fromthecomputerconnectedtotheaccesspoint dothestepsforyour operating system Windows7users a Go toStart and then in thesearchbox enter View Network Connections b Right click Local Area Connection Properties c FromtheNetworkingtab selectTCP IP4 ...

Страница 12: ...e network connections b Right clickLocalAreaConnectionsandselectProperties c Select Internet Protocol Version 4 TCP IPv4 and select Properties 3 EnteranIPaddress subnetmaskforyourcomputeroftheformat 192 168 224 xxx wherexxxisanaddressonthesamesubnetastheaccess point andthenclickApply Caution Do not use 192 168 224 160 It is the default address of the access point 4 Fromacommandpromptwindow pingthe...

Страница 13: ...4GHzand5GHzradioLEDsgooff Thisshowsthat thesystemisready LED operation during client association and data traffic Duringclientassociationanddatatraffic LEDsoperatethisway Whenclientsassociate theappropriateradioLEDcomeson After theLEDison theappropriateLEDblinksto indicatethedaterate Whenno clients areavailable the radio LEDstays off LED operation duringa firmware upgrade Duringafirmwareupgrade th...

Страница 14: ...HotPoint 5200 access point setup 8 HotPoint5200AccessPointHardwareInstallationGuide ...

Страница 15: ...s point 8 MakesureyoucanconnecttothewirelessLANorInternet Warning Qualified professionalsmust installHotPoint5200access points Failuretoinstallthisequipmentproperlycan resultin equipmentdamage personalinjury ordeath Electrical shock hazard warning This device connects to non insulatedvoltagesofsufficientmagnitudetobeariskoflethalelectric shock to persons Warning Do not install Firetide products wh...

Страница 16: ...hort circuitwithintheequipmentconnectedtotheantenna TheHotPoint5200 accesspointhaslightningprotection Makesurethatallequipment connectedtotheHotPoint5200accesspointhasthesamelevelof protection Use10AWGground wireand corrosion resistant connectors to connect the base of the antenna pole or tower directly to the building protective ground ortooneormoreapprovedgroundingrods RefertotheNationalElectric...

Страница 17: ...to which the node is attached is not properly grounded thenodecanbedamagedbyapowersurge Togroundanode 1 Calculatethecorrectgaugeofwiretobeusedinthisprocedure Refertothe NationalElectricalCodeforgroundinginformation Caution Thecertified installer is responsiblefor the correct calculation ofthewiregaugeandotheraccessoriesthatmightberequiredto ensureproperearthground 2 Terminateallantennaconnectors S...

Страница 18: ...enna connector1to2 h Repeat for second radio ifpresent i IfyouarenotusingRadio2 terminateallthreeantennaconnectors with 50 Ohm terminators 3 Removethegroundscrewfromthebottompanel 4 Insertthegroundlugfortheenclosure 5 Tightenthegroundscrewtosecurethegroundlugtothenode To earth ground 6 Crimpthelugthatholdsthewirefromantennaconnector3andthe enclosure ...

Страница 19: ...rtifiedinstallerforgrounding materialsforyourapplication Nowyouarereadytoweatherproofthecableconnections Requiredtools Common tools used for installations include 1 2 inchopen endwrench 7 16 inopen endwrench 3 8 inchopen endwrench Phillips screwdriver Channel lockorslip jointpliers RJ 45crimping tool and maleplug Waterproofingtapeorbutylmastictoweatherproofconnections ...

Страница 20: ...nceforearthground requirements and electricity Note Collect all tools before you install the access point 1 Toa polethatyou caninstallatapermanentoutdoor site attachthese items U boltsandmountplatefortheaccesspoint Antennas PoEinjector Caution The PoE injector is not weatherproof Do not expose it to rain ordirectsunlight Anyotheraccessories suchasanenclosureforthePoEinjector that needsto goonthepo...

Страница 21: ...iewrapstokeepthecablestidy 4 Givethe accesspointpower If PoEisconnectedcorrectly theLEDs onthe PoE injectorglow 5 PutweatherproofingaroundthePoEconnection Caution The PoE injector is not for outdoor use 6 Verifythattheaccesspointworks Pingthe IP address OpentheWebinterface Installing a HotPort 5200 access point to a pole or wall TheHotPort5200accesspointhasatwo piecemountassembly Onehalfofthemount...

Страница 22: ...aroundthemountingpole TheU boltsare largeenoughtoaccommodatelargepoles Thenextfigureisatopviewofa pole and mount plateand the hardware for oneside of the U bolt Put the hardwareonbothsidesoftheU bolt Note Ifyou installtheaccesspointtoasmall diameterpole youmusteithercut the U bolts to length or usefour additional spacer nuts not included ...

Страница 23: ...ntingsystemconsistsofapoleclampassembly apivotlink andan antenna bracket Requiredmaterials flatwashersandlockwashers Toattachanantennatoa mast 1 Attachthepivotlinktothepoleclampassembly Putaflatwasherunderthe bolt head Underthenut put a flat washer and lock washer 2 Attachthepoleclampassembly tothepole Putaflatwasherunderthebolt heads andunderthenutsputaflatwasherandlockwasher 3 Attachtheantennabr...

Страница 24: ...ble to the Radio 1 side left of theaccesspoint ForaMIMOantennacable useallthreeantennaconnectors ForanOFDMantennacable attachthelightningarrestortoantenna connector 1 3 Repeat step 2 for Radio 2 right 4 Ifanyantennaconnectorsarenotconnectedtoalightningarrestor installa 50Ohmterminatortoeachuncoveredantennaconnector Youarereadytoweatherproofalloftheconnections See Weatherproof procedures onpage17 R...

Страница 25: ...ccess point Put weatherproofing where lightningarrestorandmeshnodemeet lightningarrestorantennacablemeet Best practice You can use colored tape for easy identification of the connectors fromthe meshnodetotheantenna Butylmasticisasyntheticrubbersealantthatyoucanusetomakeaconnection weatherproof Itisslightlysticky andstays flexible it bondstoitselftomakea goodseal Butylmasticandalayerofelectricaltap...

Страница 26: ...esfuturechangeseasierthanmastictapeputdirectlyonthecable Vinyl electricaltapeasacoveroverthemastictapepreventsthemasticfrommelting in hot weather Rubbersplicingormastictape alsoknownasself amalgamating self sealing self fusing non vulcanizedtape Pencilorwoodendowelforsmallclearances Cleaning supplies if necessary Laptop running HotView software Makingaweatherproofantennaconnection Youneedtoputtape...

Страница 27: ...d to approximately2 5 cm 1inch of cable Overlap the tape by 40 with eachturn Note Wrap the electrical tape on a pencil or wooden dowel when you have little clearance Note Tomakeastrongwatertightconnection keepahighleveloftensioninthe butylmasticwhenyoustretchitoverthecableandconnector 6 Tightlywrapalayerofmastictapeovertheelectricaltape 7 Wrap a layer of electrical tape smoothsideout sticky sidein...

Страница 28: ...leandconnectors areclean Cleanoff oil water grease and dirt 3 Wrap a layer of electrical tape sticky side out over the arrestor to node connectorandwrapapproximately2 5cm 1inch ofcable Overlapthetape by 40 with each turn 4 Repeatfortheantennacabletoarrestorconnection Note Tomakeastrongwatertightconnection keepahighleveloftensioninthe butylmasticwhenyoustretchitoverthecableandconnector 5 Tightlywra...

Страница 29: ...Wrap a layer of electrical tape smoothsideout sticky sidein overthe mastic tape 7 Wrapasecond layerof electrical tapeoverthefirst layerofelectrical tape Thelightningarrestorconnectionsarereadyforinstallationinanoutdoor environment ...

Страница 30: ...Weatherproof procedures 24 HotPoint5200AccessPointHardwareInstallationGuide ...

Страница 31: ...esetyouneed Paper clip stiff wire or thinpiece of plastic orwood Computer with HotView Pro Ethernetcable Screwdriveroradjustablewrench dependsonmodelofnode Todoahardwareresetforanoutdoornode 1 Supplypowertothenode ThepowerLEDcomeson Afteroneminute thenodeisreadytobereset 2 Dothestepcorrectforthemodelofnode Ifthenodehasaresetscrew useascrewdrivertoremovethescrew Ifthenodehasapressurevalve useyourfi...

Страница 32: ...ubleshooting Improving client experience and device performance Iftheaccesspointdisconnectsclientsrepeatedly changetheRTS CTSvalueto 128 Toimprovedeviceperformance assignspecificchannelstotheaccesspoint Do not use theautomatic channel selection feature auto ...

Отзывы: