![FireRock FIREROCK RUMFORD Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/firerock/firerock-rumford/firerock-rumford_installation-specification-and-operation-manual_2292101030.webp)
30
LITEROCK INSTALLATION METHOD
(CONTINUED)
FLUSH HEARTH WITH LITEROCK RISER
If the design calls for a flush hearth, special consideration must be taken before lowering and setting the LiteRock on the joist
system. When calculating flush hearth height, be sure to account for both the 3” LiteRock riser, the 3 3/4” base plate, and the 2 1/2”
thick firebrick floor (a total of 9 1/4”).
Whether using a flush hearth or a raised hearth, a noncombustible hearth extension must cover the combustible floor at least 20”
out in front of the finished firebox opening and 8” beyond the finished sides of the opening.
IMPORTANT:
When installing the LiteRock Riser as
a flush hearth application, the noncombustible hearth
extension
must
be supported by noncombustible materials
(Figure 16.6). All materials that abut the fireplace or riser
material
must
be noncombustible.
The FireRock base plate
is mandatory
for the LiteRock
Installation Method. Failure to use a base plate with this
installation method may result in a fire or explosion,
causing property damage, personal injury, or loss of life.
FIREBRICK
SUPPORT EXTENSION WITH
NONCOMBUSTIBLE MATERIALS
UL 103 LISTED METAL CHIMNEY
NONCOMBUSTIBLE
HEARTH EXTENSION
FINISHED FLOOR
LITEROCK RISER
28.5”
20”
1.5”
3”
3.75”
2.5”
9.25”
50”
FIGURE 16.6
8” FROM
OPENING
3” LITEROCK RISER
FIREBRICK
8” FROM
OPENING
FIGURE 16.7
Содержание FIREROCK RUMFORD
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 39: ...39 FIREPLACE PARTS CONTINUED CHIMNEY BLOCK SIDE ELEVATION PLAN ISOMETRIC...
Страница 40: ...40 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...46 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 47: ...47 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 48: ...Version 2 1 10 2019...