background image

4 2

Optional Equipment

Travis Industries

9 3 5 0 8 1 0 3

1 5 1 0 0 2

4

Remove the pilot orifice following the instructions below.  Replace with the propane pilot orifice.  The
propane conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice.  The
.016Ó orifice is preferred because it allows for greater pilot adjustment.

Remove the pilot 

hood assembly by 

unscrewing the two 

attachment screws.

Pilot Orifice

LP (Propane) Orifices

Pull the pilot orifice 

retainer and pilot orifice 

upwards to remove.

Pilot Orifice 
Retainer

Phillips 
Screwdriver

Pilot Hood 

Assembly

1

1

P

L

Orifice Identification:

1

6

P

L

(preferred)

NG (Natural Gas) Orifices

1

8

N

2

1

N

(preferred)

5

Install the logs and embers.

6

Replace glass and face.

7

Remove the regulator from the front of the gas control valve.  Replace with the propane regulator,
using the new gasket and screws included with the regulator.  

NOTE: Leak test this area after

the heater is installed, gas is connected, and the main burner is lit.

These screws hold the 
regulator in place.

NOTE: use the new 
screws included with 
the regulator.

Phillips 
Screwdriver

PILOT ADJ

T

O

L

PI

ON

OFF

VENT

HI

LO

VENT

HI

LO

Align the regulator 
gasket so it is flat 
and the two tabs fit 
through the two 
holes on the 
gasket.

Regulator Gasket

NOTE: use the new gasket 
included with the regulator.

LP (propane) regulators have a 
11.0 2.7 stamped here.

NOTE: These holes strip 
easily.  Use a hand 
screwdriver and tighten 
each screw evenly.

Содержание 36 DV-XL (Direct Vent Extra Large)

Страница 1: ...oline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation must be performed by a qualified installer service agency or the gas supplier IF YOU SMELL GAS D...

Страница 2: ...ural gas NG or for propane LP Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Direct questions about the type of fuel used to your dealer Ch...

Страница 3: ...he thermopile and thermocouple see the illustration to the left If it does not turn the gas control valve to OFF and call your dealer AAA AA AA A A A A This unit is not for use with solid fuel Do not...

Страница 4: ...ert Term with Two Elbows 6 5 8 Dia 21 Horizontal Terminations with 8 Dia Vent 22 Vent Termination Requirements 23 Gas Line Requirements 24 Fuel 24 Gas Line Connection 24 Gas Inlet Pressure 24 Electric...

Страница 5: ...0 BTU Input Per Hour from high to low 23 000 43 000 23 000 43 000 BTU Output on High with blowers on 34 142 34 142 Efficiency with blowers on Up to 79 Up to 80 AFUE Annual Fuel Utilization Efficiency...

Страница 6: ...s must be met simultaneously The order of installation is not rigid the qualified installer should follow the procedure best suited for the installation Packing List Propane Conversion Kit Log Set Log...

Страница 7: ...as line include an extra 3 length for hookup NOTE if venting directly to the rear make sure there is a min 8 5 8 space centered behind the fireplace for the wall thimble If a 90 elbow is used directly...

Страница 8: ...AA 11 1 4 46 1 4 43 19 5 8 Fireplace includes 1 2 standoffs 12 3 4 14 1 2 65 1 2 Raised Fireplaces The fireplace and hearth if desired may be placed on a platform designed to support the fireplace 250...

Страница 9: ...AAAAAA AAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAA AA AA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAA...

Страница 10: ...s shown on page 12 add 1 8 to each dimension AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AA AA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAA...

Страница 11: ...AAAA The overlap is 1 1 2 along the top of the face NOTE Do not tuck tile underneath the face on the bottom there will be a 1 2 air space below the access door You may do this on the sides and top but...

Страница 12: ...the face angles at the top corners of the glass see the illustration below AAAAAAA AAAAAAA AA AA AA AA AA AA Remove these four screws from the face angle Phillips Screwdriver Bend the face angle up an...

Страница 13: ...A Note how the tile facing fits behind the face on the side and top and butts up to the face on the bottom When fully installed there will be a 1 2 air space below the access door on the face Do not b...

Страница 14: ...hearth installation is correctly completed there will be a 1 2 air space below the access door on the face Do not block this air space it is required for access door opening and proper air flow 3 8 Ti...

Страница 15: ...e mantel requirements listed in this manual Combustible Mantels Combustible Mantel 30 Arch face 28 1 2 Rectangular face 24 Min Arch Faces 22 Min Rect Faces Max Mantel Depth is 8 Non Combustible Mantel...

Страница 16: ...Diameter Vent for details Part Numbers are listed below Straight Lengths 1208B 6 Pipe Length Black 1207B 9 Pipe Length Black 1206B 12 Pipe Length Black 1204B 24 Pipe Length Black 1203B 36 Pipe Length...

Страница 17: ...Minimum framing for fire stop Maintain a minimum 1 clearance from vent to any combustible 8 5 8 or 10 8 5 8 or 10 Apply high temperature silicone to the inner and outer pipe before assembling the sec...

Страница 18: ...e and move it so the correct notch falls into the slot on the adjustment bracket This restrictor is in position 1 This restrictor is in position 2 AAAAA AAAAA AAAAA AAAAA To adjust lift up on the adju...

Страница 19: ...d upon lab tests The ideal restrictor position may vary slightly especially when the termination is near the demarkation line Four 45 Offsets Restrictor Position 3 AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAA...

Страница 20: ...eet 0 feet 12 max 5 feet 0 feet 12 max Use Restrictor Position 1 9 max 9 max 5 feet 10 feet 5 feet 10 feet 0 feet Warning When an elbow is used directly off the top of the fireplace a 2 clearance is r...

Страница 21: ...AAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAA...

Страница 22: ...AAAAAAAAAAAA 5 feet 0 feet 0 feet 25 max 5 feet 0 feet 25 max Restrictor Position 3 NOTE Horizontal sections require a 1 4 rise every 12 of travel The maximum vertical height is 20 The maximum horizon...

Страница 23: ...over a walkway or driveway shared by an adjacent building I Minimum 48 clearance from any mechanical air supply inlet 72 for Canada J Minimum 36 clearance above and 48 below and to the sides of non m...

Страница 24: ...installed behind the access door inside the fireplace 13 3 4 Gas Control Valve PILOT ADJ VENT TO L P I O N O F F H I L O 3 8 M P T to 1 2 O D Fitting Factory installed The 1 diameter access hole is lo...

Страница 25: ...ower source through this cable clamp Once the wires are attached tighten the clamp to secure the cable Replace the cover removed in step a Attach the common white ground exposed or green wires and hot...

Страница 26: ...up and away Set the glass aside to prevent damage Glass Replacement Make sure both bottom latches are facing upwards Position the glass at a 45 angle and lay it on the two tabs below the firebox When...

Страница 27: ...ace the kibbles directly over the burner holes AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA One Strip Approximately 7 1 2 by 1 1 2 AAAA AAAA AAA AAA Two Strips Approximately 3 by 1 1 2 Preparing th...

Страница 28: ...utside attachments on the side There is no center attachment for rectangular faces Arch Faces Use the inside attachments on the side and the attachment at the center of the face Phillips Screwdriver 5...

Страница 29: ...Dealer for a remedy If the vent configuration is installed incorrectly the vent may cause the flames inside the fireplace to lift or ghost a dangerous situation Inspect the flames after installation...

Страница 30: ...OFF Blower Knob HI Blower Knob This knob controls the speed of the internal convection blower that pushes the heated air into the room On Off Switch This control is used to turn the fireplace on and...

Страница 31: ...s on the cover IF YOU SMELL GAS c Turn the gas control knob to the PILOT position and press the knob in this will allow gas to flow to the pilot light Press the red button on the pilot igniter repeate...

Страница 32: ...main burner on and off manually After the pilot has been started See the instructions included with the remote for details on operation For systems with wall thermostats use this switch to control th...

Страница 33: ...rn the dial all the way counter clockwise until it clicks off HIGH The high position is all the way counter clockwise without clicking off LOW Turn the dial all the way clockwise Normal Operating Soun...

Страница 34: ...ealer 4 Clean the burner tube especially the burner holes and inspect the following Check for burner pan holes that are cracked severely warped or corroded Make sure the burner assembly is not warped...

Страница 35: ...of the two remote control batteries is dead See Starting the Pilot Light See Starting the Pilot Light Turn the ON OFF switch to ON Use the remote closer to the fireplace See the remote control instruc...

Страница 36: ...off using the electricity generated by the thermopile The ON OFF switch remote control or thermostat control the circuit to the main burner ON OFF MAIN BURNER PILOT ADJ VENT TO L P I O N O F F H I L O...

Страница 37: ...nd blower wiring as above Hot black Common white Ground green Fireplace Replacement Parts List Air Shutter Assembly 93006006 Orifice Gas 48 LP 93006010 Blower Convection w Mounting Plate 97300102 Orif...

Страница 38: ...the appliance should be located out of traffic and away from furniture and draperies This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance This vente...

Страница 39: ...micals b The unit is subject to submersion in water or prolonged periods of dampness or condensation c Any damage to the unit combustion chamber heat exchanger or other components due to water or weat...

Страница 40: ...trips and kibbles if installed page 27 2 Remove the burner see illustration below Remove the screw holding the burner in place Remove the grate and cast brick floor a b c NOTE When replacing the burne...

Страница 41: ...in place over the orifice Loosen the air shutter control see page 29 1 2 Wrench Use a 1 2 open end wrench to unscrew the orifice Orifice Air Control Shutter 1 8 4 8 The new LP orifice has 48 stamped o...

Страница 42: ...Gas Orifices 1 8 N 2 1 N preferred 5 Install the logs and embers 6 Replace glass and face 7 Remove the regulator from the front of the gas control valve Replace with the propane regulator using the n...

Страница 43: ...y PILOT ADJ TO L P I O N O F F Standard Screwdriver Micro 1 16 Standard Screwdriver A Cover Screw Cover Screw Gasket Needle Valve Thermopile Pilot Hood 3 8 Thermocouple The pilot flame should touch on...

Страница 44: ...alls Heat Duct Electrical Wiring Blower Box Maximum Duct Length 20 1 Determine the route for the heat duct using the illustration below as a guide A A A A A A AA AA A A A A A AA AA AA AA AA AA AA AA A...

Страница 45: ...AA AA 5 1 4 16 This blower was designed for framing on 16 centers construct additional framing if needed c Slide the blower with wires into the hole cut in step a Attach with four screws AA AA AA AA...

Страница 46: ...place 1 4 Nutdriver Remove and discard the cover plate Starter Ring 4 Install the air duct Each section when joined must be attached with three screws and duct tape U L 181A P or equivalent Secure the...

Страница 47: ...r with the current CSC22 1 Canadian Electric Code in Canada Warning Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup Rheostat Junction Box Hot black Common...

Страница 48: ...ow to wire the rheostat NOTE There are two types of junction boxes use the appropriate junction box for your installation a Force the sheathed cable through one of the locking flaps on the junction bo...

Страница 49: ...x connector Then attach the molex connector to the fireplace c d Standard Screwdriver Power Source for Fireplace Remove the cover from the fireplace junction box Note you may need to loosen this cable...

Страница 50: ...of the wire to the two posts the jumper wire was attached to 1 5 4 2 PILOT IGNITER ON OFF Green Jumper Wire Wire Back of on off switch Side of Fireplace Faceplate Route the wire through the gas inlet...

Страница 51: ...ater turns on Decorative Firebacks Part 98500729 Classic 98500728 Firebrick Turn the gas control valve to OFF prior to conducting any service The decorative cast fireback attaches to the walls of the...

Страница 52: ...ontal Vent Termination Requirements 23 How this Fireplace Works 36 Vent Lengths 18 Installation Options 5 Items Required for Installation 6 Leaking Gas See Inst on Cover Listing Information 38 Locatio...

Отзывы: