4 2
Optional Equipment
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The
propane conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice. The
.016Ó orifice is preferred because it allows for greater pilot adjustment.
Remove the pilot
hood assembly by
unscrewing the two
attachment screws.
Pilot Orifice
LP (Propane) Orifices
Pull the pilot orifice
retainer and pilot orifice
upwards to remove.
Pilot Orifice
Retainer
Phillips
Screwdriver
Pilot Hood
Assembly
1
1
P
L
Orifice Identification:
1
6
P
L
(preferred)
NG (Natural Gas) Orifices
1
8
N
2
1
N
(preferred)
5
Install the logs and embers.
6
Replace glass and face.
7
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator.
NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
These screws hold the
regulator in place.
NOTE: use the new
screws included with
the regulator.
Phillips
Screwdriver
PILOT ADJ
T
O
L
PI
ON
OFF
VENT
HI
LO
VENT
HI
LO
Align the regulator
gasket so it is flat
and the two tabs fit
through the two
holes on the
gasket.
Regulator Gasket
NOTE: use the new gasket
included with the regulator.
LP (propane) regulators have a
11.0 2.7 stamped here.
NOTE: These holes strip
easily. Use a hand
screwdriver and tighten
each screw evenly.