Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
Horizontal Terminations using 6-5/8Ó Diameter Vent
Use a single 90¡
elbow (NOTE:
an additional 45¡
elbow may be
used on the
horizontal run).
The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.
NOTE:
¥ Horizontal sections require a 1/4" rise every 12" of travel.
¥ The maximum vertical length is 5'.
¥ The maximum horizontal length is 12'.
¥ Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
5 feet
0 feet
0 feet
12' (max)
5 feet
0 feet
12' (max)
Use Restrictor
Position #1
9' (max)
9' (max)
5 feet
10 feet
5 feet
10 feet
0 feet
Warning:
When an elbow is used directly off
the top of the fireplace, a 2"
clearance is required above the
vent (1" below and to the sides).
3 foot length (max)
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
5 feet
0 feet
0 feet
12' (max)
5 feet
0 feet
12' (max)
Use Restrictor
Position #1
9' (max)
9' (max)
5 feet
10 feet
5 feet
10 feet
0 feet
Natural Gas
Installations
Propane (LP)
Installations
NOTE:
¥ Horizontal sections require a 1/4" rise every 12" of travel.
¥ The maximum vertical length is 5'.
¥ The maximum horizontal length is 12'.
¥ Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
NOTE:
Units using LP must have a 1'
vertical section directly off the top
of the fireplace.