![FireplaceXtrordinair 36 DV-XL (Direct Vent Extra Large) Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/fireplacextrordinair/36-dv-xl-direct-vent-extra-large/36-dv-xl-direct-vent-extra-large_owners-manual_2291978041.webp)
Optional Equipment
4 1
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
3
Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice
(#48 - it has "48" stamped on it) and tighten in place with a 1/2" open end wrench. Slide the
adjustable shutter back in place over the orifice.
Loosen the air shutter
control (see page 29).
1/2" Wrench
Use a 1/2Ó open end wrench
to unscrew the orifice.
Orifice
Air
Control
Shutter
1/8
48
The new LP orifice has
Ò48Ó stamped on it.
The old NG
orifice has Ò1/8Ó
stamped on it.
Apply thread
sealant to the
new orifice
prior to
installation.
a
b
c
d
Rotate the air control shutter
away from the orifice.
NOTE:
Screw the LP orifice in so the
orifice shoulder protrudes
5/16Ó (indicating full insertion).
5/16Ó