1 8
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 3
1 5 1 0 0 2
Approved Vent Configurations
Restrictor Position
¥
A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures
proper combustion for all vent configurations. Depending upon the vent configuration, you may be
required to adjust the restrictor position. The charts for acceptable vent configurations detail the
correct vent restrictor position.
With the fireplace cool, reach below
the burner pan to the left side.
To Adjust the Restrictor:
To Access the Restrictor:
1
2
NOTE:
The fireplace is
shipped with the restrictor in
position #1 (fully open).
Determine the correct restrictor position (see the charts under
"Approved Vent Configurations" - the factory position is #1).
Lift up the adjustment plate and move it so the correct notch falls into
the slot on the adjustment bracket.
This restrictor is in position 1.
This restrictor is in position 2.
AAAAA
AAAAA
AAAAA
AAAAA
To adjust , lift up on the adjustment plate.
Adjustment Plate
Adjustment Bracket
Position #3 is
this notch.
Elbows
¥
A maximum of two
90¡ elbows or four
45¡ offsets may be
used. See the
vent configurations
for details.
NOTE
: one 45¡
elbow may be used
between two
horizontal
sections.
Measuring Vent
Lengths
* NOTE
:
All measurements are for 6-5/8" diameter vent except for those
marked with an asterik (*), which are for 8".
Vent
Horizontal
Run
EXAMPLE
:
Two 4' lengths are 7' 10-1/2"
long, but when attached to
the vent system add 7' 9" to
the vent height.
Vent
Height
Elbows add 3" to the
length of the vent system.
3"
3"
Side
View
9-5/8"
11-5/8"*
1-1/2"
1-1/2"
Vent Length
(4', 3', etc.)
Vent sections overlap
each other by 1-1/2"
46-1/4"
8-3/4" (10-3/4"*)
wide with 1-1/2" to
3-3/8" of overlap
Starter
Section
12-3/8" tall
with 1-1/2"
of overlap
Adds 8" to System Height
(Total = 9-1/4" Tall)