Finalizing
the
Installation
(for qualified installers only)
13
© Travis Industries
4161018
100-01436
Air Cooled Chimney Requirements (8” Inner Dia., 12” Outer Dia.)
Part Numbers (available through Travis Industries)
Chimney Components
Part #
Anchor Plate – Air Cooled Chimney -
REQUIRED
98900016
Cooling Duct Kit -6” Diameter -
REQUIRED
98900108
48” Chimney Section
98900001
36" Chimney Section
98900002
24" Chimney Section
98900003
18" Chimney Section
98900004
12" Chimney Section
98900005
30° Offsets / Elbows (Qty 2)
98900006
Firestop (90°)
98900007
Firestop (30° - for angled sections)
98900008
Storm Collar
98900009
Round Termination Cap
98900010
Flashing 0-6/12 (for flat roofs up to 6/12 pitch - 26.5°)
98900011
Flashing 7-12/12 (for roofs 6/12 pitch to 12/12 – 26.5° to 45°)
98900012
Attic Insulation Shield
98900015
Anchor Plate Installation
The air-cooled chimney requires an anchor plate that includes a cooling duct inlet. Attach the anchor
plate to the top of the fireplace with the four included sheet-metal screws (see illustration below).
The cooling duct inlet can be directed to any direction (typically it is directed to the right rear).
Seal the fireplace connection with high-temperature silicone.
Seal the flue liner with furnace cement.
High-Temperature
Silicone
Use high-temperature silicone to
seal the anchor plate.
Furnace Cement