1.3 

Features and Benefits 

 

  Our Patented WideBand IR Detection Technology for detecting 

both

 hydrocarbon and non-hydrocarbon 

fires in industrial environmental conditions. 

  Uses the proven Quantum WideBand IR sensors as the highly successful Model FS7 Detectors, which 

have over 25,000 successful installations in Semiconductor Cleanroom applications worldwide since 1996. 

  False Alarm Immunity due to the patented software signal processing algorithms and due to full WideBand 

Spectrum sensor array with WideBand IR sensor wth twin Visible sensors, and twin NearBand IR sensors. 

  Twin highly integrated Microprocessors reduce the number of discrete components, provides larger 

software algorithm programming and memory capacity, and provides redundant processor self-checking. 

  Lower price Detector replacement for Model FS7 applications. 

  Low power consumption, 24Vdc, 47mA nominal (1.13 W), 88mA max ALARM current (2.11 W). 

  Multiple Detector output options for a variety of industrial applications. 

  Up to 32 unique digital communication addresses when RS-485 communication is used.  

  Optional RS-485 output available (FireBus

II

 protocol) for use with the FS2100X System CPX Din Rail 

Panels and the FS7-130-SX Controller. 

  Digitally stepped 4-20mA (current sinking) output (optional). 

  Latching or non-latching mechanical (dry contacts) relay outputs (same reliable relays as used in the 

Model FS7-2173-2RP Detectors). 

  Class 

I

, Zone  2 polypropylene housing (sames as proven Model FS7 housing) for Clean Room, 

Semiconductor Wet Bench and Wet Chemical applications. 

  Three Separate Bright LEDs (Red, Yellow, Blue) for quick, easy identification of ALARM, Fault and Normal 

status for semiconductor clean room environments. 

  Our Windows® based PC Software for remote FSX diagnostics and data retrieval. 

  Designed, Manufactured, Tested, and Patented by Fire Sentry Corporation (30 years of proven fire / flame 

detection product excellence worldwide). 

1.4 

Applications 

The applications for the FS17X Fire and Flame Detectors include:  

Clean Rooms 

Gas Cabinets 

Hydrogen Gas Cabinets 

Hydrogen Plants 

Hydrogen Storage 

Semiconductor Wet Benches 

Semiconductor Wet Chemicals 

Silane Gas Cabinets 

Silane Gas Manufacturing 

Содержание FS17X

Страница 1: ...t 2012 All Rights Reserved Fire Sentry Corporation 23311 La Palma Avenue Yorba Linda California 92887 Telephone 714 694 2700 Fax 714 694 2701 www firesentry com FS17X WideBand IRTM Multi Spectral Infr...

Страница 2: ...ns such as FS2 FS2X FS2X FS3 FS3X FS3X FS4 FS4X FS4X FS5 FS5X FS5X FS6 FS6X FS6X FS7 FS7X FS7X FS8 FS8X FS8X FS9 FS9X FS9X FS10X FS10X FS11 FS11X FS11X FS12 FS12X FS12X FS14 FS14X FS14X FS15 FS15X FS1...

Страница 3: ...pecifications 2 1 2 5 Area Classification 2 1 3 Features Benefits 3 1 4 Applications 3 SECTION 2 INSTALLATION 4 2 1 Mounting Instructions 4 2 2 Detector Connections 5 2 3 Installation Practices 8 2 4...

Страница 4: ...d IP67 dust tight leak proof and water tight to 1 meter Figure 1 1 FS17X Detector FS17X Connections The Model FS17X uses an eight 8 conductor Standard Cable or an optional eight 8 conductor Cable with...

Страница 5: ...Lens 4 0 mA 0 6 mA Normal Safe no Fault no Fire 20 0 mA 0 6 mA Fireball or Fire ALARM 20 0 mA 0 6 mA Fire ALARM or Verified Fire ALARM Cable Eight 8 Conductor 24 AWG or fourteen 14 Conductor 24 AWG M...

Страница 6: ...M current 2 11 W Multiple Detector output options for a variety of industrial applications Up to 32 unique digital communication addresses when RS 485 communication is used Optional RS 485 output avai...

Страница 7: ...Physical obstructions between a fire and the Detector may cause the fire to be undetected 4 The rugged stable and calibrated Polypropylene Swivel Mount SM17 is designed specifically for the FS17X Det...

Страница 8: ...Response Fireball Relay COM COMmon Fire Verification Relay COM COMmon Current Sinking 4 20mA Orange Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally...

Страница 9: ...RS 485 Quick Response Fireball Relay COM COMmon Fire Verification Relay COM COMmon Current Sinking 4 20mA Red Fire ALARM Relay N O Normally Open Fire ALARM Relay N O Normally Open Fire ALARM Relay N...

Страница 10: ...nal A Blue Fire ALARM Relay Terminal B Brown White Fire ALARM Relay Terminal A loop through Blue White Fire ALARM Relay Terminal B loop through Yellow Fire ALERT Relay Terminal A Orange Fire ALERT Rel...

Страница 11: ...ockwise circular motion signifying the microprocessors are successfully checking out the sensors and electronics in the Detector Module 2 4 Start Up and Commissioning ATTENTION FSX Power Up After the...

Страница 12: ...ensuring all the system wiring and cabling and system control panel s are properly installed Additionally using an external test lamp eliminates the following Detector conditions 1 The fire or flame...

Страница 13: ...ding its pushbutton While watching the red ALARM LED on the face of the Detector slowly move the Test Lamp s boresight to ensure the Detector receives its full intensity UNOTE Practicing this techniqu...

Страница 14: ...isible Band and NearBand IR are used primarily to further discriminate against non fire false alarm sources As with all Fire Sentry Corporation Detectors the Model FS17X Detector senses radiant energy...

Страница 15: ...s every 10 seconds See Figure 3 1 for the location of the Blue LED Normal Operation is defined as the Detector with 24 Vdc applied and no ALARM or Fault conditions are present Flashes LED Status 1 Blu...

Страница 16: ...rt OR Moisture is inside of the Detector Housing Contact Fire Sentry Corporation to speak with a Technical Representative 5 Yellow High or Low Temperature Fault Less than 40 C or Greater than 60 C Zon...

Страница 17: ...ting should be performed using the correct Fire Sentry Test Lamp to ensure the integrity of the entire fire protection system see Note in Section 2 4 and Section 4 3 Clean the FS17X Detector window Ea...

Страница 18: ...time inconvenience commercial loss lost profits or savings or other incidental special or consequential damages arising out of or in connection with the use or inability to use such Product THIS WARRA...

Страница 19: ...gral Cable 8 conductor Kalrez O Ring P Phoenix 8 Pin Connector Relay Contact Fault N C Normally Energized Non Latching 1 Fire Relays N O Normally De Energized Non Latching 2 Fire Relays N O Normally D...

Страница 20: ...ength 1 3 meters 10 feet 2 6 meters 20 feet Standard 3 12 meters 40 feet 4 18 meters 60 feet 5 24 meters 80 feet F O Ring K Kalrez O Ring V Viton O Ring Standard E Relay Mode N Non Latching Standard D...

Страница 21: ...or is aimed properly that its view of the fire scene has not been blocked by something such as a newly installed pipe or duct storage box parked vehicle etc and its ALARM outputs are functioning prope...

Страница 22: ...v F Copyright 2012 All Rights Reserved Page 19 4 4 Drawings 4 4 1 Outline and Dimensions Figure 4 3 Outline Dimesional Drawing for Model FS17X Figure 4 4 Outline Dimesional Drawing for SM17 Swivel Mou...

Страница 23: ...ill Energize during ALARM conditions 3 Fault relay contacts shown with no electrical power applied During normal operation and with no Fault this relay will De Energize and the N O Normally Open conta...

Страница 24: ...normal operation and with no Fault this relay will De Energize and the N O Normally Open contacts will close 4 At the Fire Alarm or Process Panel connect a jumper between 24 Vdc Supply and 4 20mA Figu...

Страница 25: ...will Energize during ALARM conditions 3 Fault relay contacts shown with no electrical power applied During normal operation and with no Fault this relay will De Energize and the N O Normally Open con...

Страница 26: ...ring normal operation and with no Fault this relay will De Energize and the N O Normally Open contacts will close 5 At the Fire Alarm or Process Panel connect a jumper between 24 Vdc Supply and 4 20mA...

Страница 27: ...ault Relay Terminal A contact to B during Normal Operation Purple Fault Relay Terminal B contact to A during Normal Operation Brown Fire Alarm Relay Terminal A Blue Fire Alarm Relay Terminal B Brown w...

Страница 28: ...Fire Verification 1 5 11 Fireball 1 2 5 FireBusII 3 5 11 12 FS17X G 5 11 FS17X R 11 FS17X S 5 11 FSIM 10 H Hazardous Location s 1 High Sensitivity 2 I Input Voltage Range 2 Installation 4 7 Introducti...

Страница 29: ...Copyright 2012 All Rights Reserved Page 26 INDEX continued T Technical Specifications 2 Test Lamp 17 TL 1055X 7 9 13 17 TL 2055X 7 9 13 17 Tubing 15 16 Twin Microprocessors 3 V Verified Fire 2 VIS 2 V...

Отзывы: