MANUAL PILOT FIREBOWL
Side Mounted Ignition
•
45
•
54
•
68 NL & LL Firebowl
FRONT VIEW
TOP VIEW
8 3/4"
10"
54" DIA
SIDE VIEW
GENERAL SPECIFICATIONS
The firebowl must be installed on site, pres-
sure and leak checked by a certified gas
technician as per national and local, build-
ing, gas, fire, and safety codes and ordi-
nances.
This appliance comes supplied with a Max-
itroll 325-5AL Individual low pressure appli-
ance regulator. An additional ‘plain view’
emergency gas shut-off valve is to be sup-
plied and installed by a certified gas techni-
cian as per national and local, building, gas,
fire, and safety codes and ordinances.
BURNER & BTU SPECIFICATIONS
The burner for this appliance is assembled
and tested by:
Charles A. Hones Inc., P.O. Box 405 - 355 NY
State Route 49, Cleveland, NY 13042, (315)
623-2124
The burner is a special, stainless steel, “Yel
-
low Flame” burner, and is rated at a mini
-
mum of 150,000 and a maximum of 300,000
BTU’s. The burner is supplied with the ap
-
propriate brass orifice for use with either
natural gas (NG) or propane (LP).
OPERATING PRESSURES
• Propane: Standard operating pressure: 11
inches water column, minimum operating
pressure: 10 inches water column, maxi-
mum operating pressure: 12 inches water
column.
• Natural gas: Standard operating pressure:
6 inches water column, minimum operating
pressure: 5 inches water column, maximum
operating pressure: 7 inches water column.
HIGH-ALTITUDE OPERATION
No adjustments are required for high-alti
-
tude installation.
OVERVIEW
15
54LL Firebowl