FIRE FEATURES FIREBOWL 45 L Скачать руководство пользователя страница 12

MANUAL PILOT FIREBOWL

Side Mounted Ignition 

 45 

 54 

 68 NL & LL Firebowl

WARNINGS

12

FOR YOUR SAFETY READ BEFORE 
OPERATING

 

!

FOR YOUR SAFETY READ BEFORE 
OPERATING

 

!

FOR YOUR SAFETY READ BEFORE 
OPERATING

 

!

FOR YOUR SAFETY READ BEFORE 
OPERATING

 

!

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUC-

TIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT 

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR 

LOSS OF LIFE.

•  IMPROPER  INSTALLATION,  ADJUSTMENT,  ALTERA

-

TION, SERVICE OR MAINTENANCE CAN CAUSE INJURY 

OR PROPERTY DAMAGE. 

•  INSTALLATION  &  GAS  CONNECTION  IS  TO  BE  HARD 

PIPE  &  MUST  BE  DONE  BY  A  CERTIFIED  GAS  TECHNI

-

CIAN, QUALIFIED INSTALLER, SERVICE AGENCY OR GAS 

SUPPLIER. FOR ASSISTANCE OR ADDITIONAL INFOR-

MATION CONSULT A QUALIFIED INSTALLER, SERVICE 

AGENCY, OR THE GAS SUPPLIER.

• THIS APLIANCE IS A DECORATIVE GAS APPLIANCE FOR 

OUTDOOR USE ONLY AND MUST NOT BE USED FOR COOK

-

ING.

 

COLOMBO CONSTRUCTION CORP disclaims any responsibility 

for, and the warranty will be voided by the following actions:

• Installation & use of any damaged components.

• Modification of the burner and valve assemblies.

• Installation other than as instructed by this Owner’s Manual.

• Installation and/or use of any component part not approved 

by Colombo Construction Corp. 

ANY SUCH ACTION MAY CAUSE A FIRE HAZARD.

(See additional warranty info pg 6)

The installation of this appliance must conform with local 

codes or, in the absence of local codes, with the National Fuel 

Gas Code, ANSI Z223.1.

Solid fuels are not to be burned in this gas appliance.

The appliance should be inspected before each use for debris, 

damage, or corrosion, and at least annually by a qualified ser-

vice person. 

• INSPECT THE APPLIANCE & COMPONENTS. 

• DO NOT INSTALL DAMAGED COMPONENTS.

• DO NOT INSTALL INCOMPLETE COMPONENTS.

• REPORT DAMAGED PARTS TO DEALER.

Do NOT use this appliance if any part has been under water.  

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and any 

gas control which has been under water.

More frequent cleaning may be required as necessary. It is im

-

perative that control compartment, burners and circulating air 
passageways of the appliance be kept clean to provide for ad-

equate combustion and ventilation air. 

This appliance is only for use with the type of gas indicated 

on the rating plate. This appliance is not convertible for use 
with other gases.

The appliance and its individual shut-off valve must be discon-
nected from the gas supply piping system during any pressure 

testing of that system at test pressures in excess of ½ psi.

The appliance must be isolated from the gas supply piping sys-
tem by closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping system at test pres-

sures equal to or less than ½ psi.

A test gage connection shall be furnished downstream of the 

gas appliance pressure regulator for measuring gas pressure. 

The connection shall be a 1/8 inch NPT plug or cap with cleanly 
cut tapered pipe threads in accordance with the Standard for 

Pipe Threads, General Purpose (Inch), ANSI/ASME B1.20.1. 

If the plug is of the slotted type it shall also incorporate square 
or hex flats; or when the pressure test gage connection is pro-
vided as part of the control this pressure test gage connection 
shall be:
(a) A tapping sealed by a 1/8 inch NPT plug or cap with cleanly 
cut tapered pipe threads in accordance with the Standard for 

Pipe Threads, General Purpose (Inch), ANSI/ASME B1.20.1. 

If the plug is of the slotted type, it shall also incorporate square 
or hex flats; or

(b)  A  hose  fitting  with  a  minimum  length  of  0.355  in  (9.02 
mm)  and  a  0.355  in  (9.02  mm)  maximum/0.335  in  (8.05  mm) 

minimum outside diameter and which incorporates a sealing 

means.

The construction of the hose fitting shall incorporate an inter-

nal restriction not greater than 0.0394 in (1.0 mm) in diameter.

Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away to avoid burns or 

clothing  ignition.  Young  children  should  be  carefully  super

-

vised when they are in the area of the appliance.

Clothing or other flammable materials should not be hung 

from the appliance, or placed on or near the appliance.

Any guard or other protective device removed for servicing the 

appliance must be replaced prior to operating the appliance.

Use outside only in well ventilated area. Do not use inside house, camp

-

er, tent, garage, vehicle or any type of un-vented or enclosed area. 

Содержание FIREBOWL 45 L

Страница 1: ...able vapors or liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance CARBON MONOXIDE HAZARD Thi...

Страница 2: ......

Страница 3: ...1 22 24 25 26 28 29 31 Listing Information Purchase Agreement Warnings Warranty Information Overview Size Chart Components Control Panel Venturi Orifice Burner Pilot Pilot Guard Pilot Sighting Tube Mo...

Страница 4: ...NER PILOT SIGHTING TUBE INSIDE APPLIANCE 4 TURN GAS VALVE CONTROL KNOB ON APPLIANCE TO LOW POSITION 5 PUSH RED BUTTON FOR PILOT HOLD 6 IMMEDIATELY PUT TORCH INSIDE PILOT SIGHTING TUBE IGNITE PILOT CON...

Страница 5: ...ss from and against any claim loss damage or expense including reasonable attorneys fees resulting or arising from a breach of Buyer s warranty 2 Prices The prices specified are not subject to change...

Страница 6: ...y The Company and will not be processed if received after the expiration date The RMA number must be indi cated on the outside of the return package and a copy of the RMA in the package with product I...

Страница 7: ...insurance as the Company or Buyer may determine is reasonably necessary to insure against injury to persons and property by reason of such on site installations The policy shall be in the name of the...

Страница 8: ...located in New York County the State of New York Buyer consents to the jurisdiction of such courts and waives any defense based on lack of jurisdiction or forum inconveniens 12 Ownership of Designs Bu...

Страница 9: ...minimum operating pressure 5 inches water column maximum operating pressure 7 inches water column MANUAL PILOT IGNITION SYSTEM SPECIFICATIONS Includes Mounted instructional control panel with 3 4 gas...

Страница 10: ...emicals plastics petroleum products electronics motors vehicles fer tilizer gun powder ammunition firearms fireworks fabrics paper products wood dry vegetation etc Do not operate appliance during an e...

Страница 11: ...sed quarters the propane or natural gas required to operate the appliance as well as to post or secure the appliance from unknowing persons contacting the appliance while it is in operation or hot eit...

Страница 12: ...ssageways of the appliance be kept clean to provide for ad equate combustion and ventilation air This appliance is only for use with the type of gas indicated on the rating plate This appliance is not...

Страница 13: ...e in or near flame Do not throw foreign objects or any liquids into appliance Do not operate this appliance under the influence of alco hol or drugs The firebowl does not come supplied with rocks 100...

Страница 14: ...ons to permit the entrance of a 1 8 inch 3 2 mm diameter rod Gas supply valves must be readily accessible for hand opera tion A door on the enclosure to gain access to the gas sup ply valves is accept...

Страница 15: ...The burner for this appliance is assembled and tested by Charles A Hones Inc P O Box 405 355 NY State Route 49 Cleveland NY 13042 315 623 2124 The burner is a special stainless steel Yel low Flame bu...

Страница 16: ...MANUAL PILOT FIREBOWL Side Mounted Ignition 45 54 68 NL LL Firebowl 45 DIAMETER LL LITTLE LIP NL NO LIP 54 DIAMETER LL LITTLE LIP NL NO LIP 68 DIAMETER L LIP NL NO LIP SIZE CHART LIP OPTIONS 16...

Страница 17: ...Guard Pilot Assembly Venturi Air Mixer Venturi Air Shutter Orifice 1 2 Connection to Control Valve Gas Valve Control Knob Baso Safety Valve Maxitrol 325 5AL Low Pressure Regulator Control Panel COMPON...

Страница 18: ...LEGEND Burner Plate Pilot Lighting Button Control Panel Gas Valve Control Knob BEHIND THE FRONT PLATE LEGEND H15DA 3C Baso Safety Valve 3 4 Ball Valve Flame adjustment K16BA 48 22 Baso Thermocouple 1...

Страница 19: ...ession Tube Fitting Elbow Adapter OXYGEN INTAKE ADJUSTMENT The Venturi is factory set with a set screw Before operation check to see that the Ven turi is set in the position to the left The positionin...

Страница 20: ...ner tested prior to shipping LEGEND Burner Mounting Leg 1 Schedule 40 Stainless Steel Cross Burner 90M Stainless Steel Venturi Air Mixer LEGEND Pilot Sighting Tube Mounting Post 1 4 Gas Feed Pilot Mou...

Страница 21: ...ch keeps the lava rocks from damaging the pilot assembly PILOT SIGHTING TUBE The Pilot Sighting Tube allows you to guide the torch to the proper location to light the pilot when the firebowl is filled...

Страница 22: ...1 2 hole 5 1 2 deep in a stable mount ing platform recommended a 20 diameter sonotube concrete footing Hammer Expansion Anchor Bolt into the hole The bolt should stick out 2 1 2 Remove washer and scre...

Страница 23: ...d is installed The heat shield comes welded to the ball feet the firebowl sits on See clearances on the next page MOUNTING 23 SECTION A SECTION A A FIREBOWL EQUIPPED WITH A LOWER HEAT SHIELD IS MOUNTE...

Страница 24: ...tible materials when a heat shield is installed See page 23 for mounting a firebowl with a heat shield Test recorded temperatures with heat shield Floor temperature 150 F CLEARANCES 24 A B A B 144 COM...

Страница 25: ...ated at a minimum of 150 000 and a maximum of 300 000 BTU s The burner is supplied with the appropriate 1 4 brass orifice for use with either natural gas NG or propane LP a modified 90M stainless stee...

Страница 26: ...ntrol knob on appliance to LOW position Push red button for pilot and hold Immediately put torch inside pilot sighting tube and ignite pilot Continue to hold down button for 30 seconds or until pilot...

Страница 27: ...UT BURNER OUT TURN PLAIN VIEW SHUT OFF VALVE TO OFF OR CLOSED POSITION WAIT FOR GAS TO BURN OUT OF LINE TURN GAS VALVE CONTROL KNOB ON APPLI ANCE TO OFF POSITION ALWAYS SHUT DOWN IN THIS MANNER GAS LI...

Страница 28: ...ailable Lava rocks come in all sizes from pebbles to boulders 2 6 lava rock is the best size to use with your firebowl You will need ap proximately 100 to 200lbs for the firebowls If you are unable to...

Страница 29: ...on is correct and that pilot reliably and accurately ignites main burner Use a tooth pick or thin wire to poke out any clog or obstruction from the small holes in the burner ONLY WHEN BURNER IS OFF Ch...

Страница 30: ...at left for a normal flame pattern After visually inspecting the pilot flame and establishing it is in normal working condi tion the next thing to check is the main burner To turn the main burner on...

Страница 31: ...2 8 Baso Brass Pilot Orifce Assembly Includes NG or LP Orifice 9 1 4 O D Pilot Light Feed Tubing 10 Baso Thermocouple K16BA 48 22 PILOT GUARD SIGHTING ASSEMBLY 11 Pilot Guard 12 Pilot Sighting Tube MA...

Страница 32: ......

Отзывы: