![Fiplex DHS37-R-DU Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/fiplex/dhs37-r-du/dhs37-r-du_user-and-installation-manual_2290610032.webp)
DHS37-R-DU
28
a 3V lithium battery, button type of 20mm (CR2032) with 220mA·h. This suffices for
at least half year. When the repeater is powered, no current is drained from the
battery. So, actual battery life will depend on repeater usage. For battery
replacement, please locate battery holder between USB and Ethernet connectors on
main board. Battery positive side is UP, i.e. on holder clip.
After clicking on “Apply Changes” link, next message will appear, warning the user that
system needs to be rebooted.
Configuration
o
Apply Changes: as it is said above, this link is used to load changes to the
repeater, in configuration, tag, IP, password and date and time menus. After
any configuration change, web page will show and icon that allows user to
know if configuration has been successfully applied:
o
Reload Settings: clicking this link, repeater configuration data is refreshed.
Version: shows hardware, firmware and software versions of repeater and serial
number.
6.2 RF parameters description (Digital Master)
“Status” menu shows whole RF configuration and RF and optical links monitoring data that are
distributed along the webpage.
The first frame called “MASTER” is placed in top of webpage, showing configuration of digital
master unit. Below this, some frames titled “REMOTE 1”, “REMOTE 2”... . There is one for each
remote unit connected to the master, and configuration and status information related to each
remote can be viewed. Next figures show these frames:
Содержание DHS37-R-DU
Страница 1: ...English DHS37 R DU PS800 Digital Fiber Remote Unit User Installation Manual ...
Страница 13: ...DHS37 R DU 9 2 4 Dimensions 2 4 1 Digital Master Expansion and Remote Unit Cabinet Dimensions ...
Страница 15: ...DHS37 R DU 11 2 After attaching the bracket hang the cabinet as shown in Figure 3 Figure 3 ...
Страница 18: ...DHS37 R DU 14 B Open the cabinet cover Figure 6 C Close the cabinet cover Figure 7 ...
Страница 19: ...DHS37 R DU 15 D Secure cabinet cover Figure 8 ...
Страница 27: ...DHS37 R DU 23 Filters and fine gain settings ...
Страница 45: ...DHS37 R DU 41 ...