DHS37-R-DU
20
4.2
Starting Operation
BE SURE THAT “TO MOBILE” AND “TO BASE” PORTS ARE PROPERLY
LOADED EITHER WITH 50 OHMS DUMMY LOADS, OR RADIATING SYSTEM.
1. Turn on the repeater, connect computer to repeater through USB cable, and run Fiplex Control
Software. Check that all remote units are connected to the master through fiber optic checking link
status.
2. Enable channel filtering if needed and setup desired channel frequencies. If Fiplex Digital Fiber DAS is
used as channel selective, user has to know what frequencies are used in base station. Each channel
can be enabled independently. Channels not used can be showed / hidden using the “Show channels”
checkboxes. If remote units are on and connected through optical fiber, the corresponding uplink
frequencies will be automatically set, too.
Link status