23
ANTI-UNSCREWING ADJUSTMENT DISK LOCK
In order to prevent the adjustment disk from
being removed, which would make the rotating
parts accessible, there is an anti-unscrewing
adjustment disk lock (safe) positioned under the
adjustment disk.
COFFEE OUTLET GUARD
The coffee outlet guard must always be fixed to
the doser using the relevant screws, wich must
never be removed by the user. The removal of
the coffee outlet guard can be done by skilled
technical personnel only after disconnecting the
grinder-doser from the power supply by
unplugging. Before reconnecting the grinder-
doser to the power supply, fix the safety device
to the doser by the relevant screws.
NOISE LEVEL
EEC COUNTRIES
The maximum noise emission of our coffee
grinders and grinders/dosers measured in UNI
EN ISO 3741 reverberating chamber in
compliance with the EN 60704-1 regulations, is
compliant with the EN 60704-1 : 1998 and EN
607043 : 1996 regulations. The daily personal
noise exposure of a worker, due only to an
appliance’s limit operation of 240 min. per eight
hours, is 78 dB(A), according to ED 86/188/EEC
and ED 200311 0/EEC. Therefore during he
appliance’s normal operation, no pro-visions are
to be taken in order to prevent such risks arising
or likely to arise from noise exposure at work
(articles 3-8 of ED 2003/10/EEC).
MAINTENANCE
It is essential to check the state of the supply
cable and plug periodically. In the event the
supply cable or plug are damaged, call in skilled
technical personnel to replace them, this to
prevent any risk. In ce-certified appliances a
special tool is required to open the base plate to
get at the cable. It is recommended to use
original spare parts only. In order to assure the
lasting efficiency of the appliance, skilled
technical personnel must be called in to perform
periodical maintenance, including detailed
checks of the state of those components subject
to wear. The state of the grinding blades must be
checked periodically. Keeping the grinding
blades in an excellent state assures high-quality
grinding, resulting in greater productivity and
limited overheating.
CLEANING THE APPLIANCE
Disconnect the grinder-doser’s power supply by
unplugging it before cleaning. The appliance must
not be cleaned using water jets. Do not install the
grinder-doser in rooms where water jets are used
for cleaning. The grinder-doser must be cleaned
periodically by skilled technical personnel only.
Use perfectly clean, disinfected cloths or brushes
for cleaning. Do not use abrasive products as
these are liable to take the sheen off shiny parts.
HOPPER
Wash the hopper once it has been removed from
the appliance (unscrewing the relevant fastening
screw), using neutral soap and water, rinse
abundantly with lukewarm water and dry
thoroughly. It is advisable to clean the hopper
periodically. Once the hopper has been cleaned,
it must be attached to the upper grinding blade
holder using the relevant screw.
GRINDING SYSTEM
Remove the safety screw which prevents the
adjustment disk from being removed. Unscrew
the adjustment disk by turning it clockwise.
Having removed the upper grinding blade
holder, clean the grinding blades, threads and
the entire grinding system thoroughly using a
clean brush and cloth. Having refitted the upper
grinding blade holder in the relevant slot, screw
the adjustment disk back on, put the self-locking
screw back in whichever of the two holes on the
disk enables the best adjustment and, having
refitted the hopper and secured, adjust the
grinding as required.