42
CLEANING AND MAINTENANCE
AFTER FIRST 4 TO 8 HOURS OF OPERATION
Check and adjust clutch. See CLUTCH MAINTENANCE section.
DAILY
1. Cleaning the HydroSeeder
®
A. Fill slurry tank to center of agitator shaft with clean water.
B. Move agitator lever to full speed (
FORWARD
and
REVERSE
) to flush off inside of
tank top and walls.
C. Remove discharge nozzle and gasket from discharge boom.
D. With the engine at low idle and while pointing discharge toward an open area,
move discharge valve foot pedal to
DISCHARGE OPEN
position and engage (turn
on) the slurry pump clutch. Allow to discharge until clear water is coming out.
Do NOT engage the slurry pump clutch above 1,000 RPM's or damage
the slurry pump clutch will occur.
E. Move recirculation valve handle to
RECIRCULATION OPEN
and allow to run until
clear water is coming out.
F. Disengage (turn off) the slurry pump clutch, idle the engine, move valve foot pedal
to
DISCHARGE OPEN
position, move agitator handle to
NEUTRAL
, and turn off
engine.
G. Always remove drain plug and allow the tank to drain.
H. In freezing weather, leave main tank drain plug out and remove pump drain plugs.
Move all slurry valves to
OPEN
position.
I. Wash the outside of the HydroSeeder
®
, including the radiator, to remove any
corrosive materials.
NOTE:
Do NOT use pressurized washer to clean radiator fins or damage to
radiator fins will occur.
J. If using lime, daily maintenance should be performed after every load.
K. Clean out extension hoses.
L. Make sure all tank vents are clean and open. Do not plug or cap.
2. Lubricating the HydroSeeder
®
- See LUBRICATION AND FLUIDS CHART.
Lubrication should be performed IMMEDIATELY AFTER cleaning of the
equipment, making sure the engine is not running. Failure to comply
could result in minor or moderate personal injury. Failure to comply could also result in
product or property damage.
A. Lubricate the agitator shaft bearings located on the outside front and rear of slurry
tank.
B. Service the automatic pressure lubricator on pump as needed. See EQUIPMENT
CHECK section.
C. Check the engine oil and replenish when necessary. Change oil and filter after first
100 hours, then 500 hours thereafter. Consult the engine operator’s manual for the
correct grade of oil and the engine break-in procedure.
Содержание HydroSeeder T170 MB
Страница 4: ......
Страница 30: ...24 DISPLAY LIST SINGLE DATA FORMAT DUAL DATA FORMAT...
Страница 50: ...44 12 6 1 5 3 4 3 7 11 8 2 9 10 Figure 9 Lubrication and Adjustment Points...
Страница 57: ...51 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 58: ...52 8 ft 10 in 269 cm 16 ft 8 in 508 cm 7 ft 9 in 236 cm...
Страница 60: ...54 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 66: ...T170 MB0521 Rev B WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 60 1 3 4 5 2 6 7 8 2...
Страница 72: ...T170 MB0521 Rev B WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 66 1 2 3 4 5 6 7 8 9 10 11...