13
3. EXTENSION HOSE OR HOSE REEL THROUGH REMOTE PORT:
Flow is through the open recirculation valve with
no flow through the closed boom discharge valve
(Figure 6). Flow through the hoses is started and
stopped by engaging or disengaging the slurry
pump clutch. The operator controls the spray
volume and flow by adjusting the remote ball valve
attached to the end of the hose and by adjusting the
engine RPMs. The open recirculation valve allows
all of the excess flow and pressure to be directed
back into the tank.
Recirculation valve must
be open and material
should be fl owing back into tank when using a
remote valve. A closed or plugged recirculation
line will cause extreme heat. Failure to comply
WILL cause severe personal injury or death.
Figure 6 – Discharge Through
Extension Hose or Hose Reel
TANK
CLOSED
OPEN
FLOW
FLOW